Literature DB >> 23246753

Calibration and field evaluation of Polar Organic Chemical Integrative Sampler (POCIS) for monitoring pharmaceuticals in hospital wastewater.

Emilie Bailly1, Yves Levi, Sara Karolak.   

Abstract

The Polar Organic Chemical Integrative Sampler (POCIS) is a new tool for the sampling of organic pollutants in water. We tested this device for the monitoring of pharmaceuticals in hospital wastewater. After calibration, a field application was carried out in a French hospital for six pharmaceutical compounds (Atenolol, Prednisolone, Methylprednisolone, Sulfamethoxazole, Ofloxacin, Ketoprofen). POCIS were calibrated in tap water and wastewater in laboratory conditions close to relevant environmental conditions (temperature, flow velocity). Sampling rates (R(s)) were determined and we observed a significant increase with flow velocity and temperature. Whatever the compound, the R(s) value was lower in wastewater and the linear phase of uptake was shorter. POCIS were deployed in a hospital sewage pipe during four days and the estimated water concentrations were close to those obtained with twenty-four hour composite samples.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23246753     DOI: 10.1016/j.envpol.2012.10.025

Source DB:  PubMed          Journal:  Environ Pollut        ISSN: 0269-7491            Impact factor:   8.071


  7 in total

1.  Monitoring contaminants of emerging concern from tertiary wastewater treatment plants using passive sampling modelled with performance reference compounds.

Authors:  Tamanna Sultana; Craig Murray; M Ehsanul Hoque; Chris D Metcalfe
Journal:  Environ Monit Assess       Date:  2016-12-01       Impact factor: 2.513

2.  Determining the suitability of a polar organic chemical integrated sampler (POCIS) for the detection of pesticide residue in the Ishikawa River and its tributary in Osaka, Japan.

Authors:  Yoshinori Yabuki; Junko Ono; Takashi Nagai; Keiya Inao; Shinji Tanimori
Journal:  J Pestic Sci       Date:  2018-02-28       Impact factor: 1.519

3.  Field application of passive SBSE for the monitoring of pesticides in surface waters.

Authors:  A Assoumani; M Coquery; L Liger; N Mazzella; C Margoum
Journal:  Environ Sci Pollut Res Int       Date:  2014-09-19       Impact factor: 4.223

4.  Aquatic passive sampling of perfluorinated chemicals with polar organic chemical integrative sampler and environmental factors affecting sampling rate.

Authors:  Ying Li; Cunman Yang; Yijun Bao; Xueru Ma; Guanghua Lu; Yi Li
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-05       Impact factor: 4.223

5.  Presence of active pharmaceutical ingredients in the continuum of surface and ground water used in drinking water production.

Authors:  Heidi Ahkola; Sirkku Tuominen; Sanja Karlsson; Noora Perkola; Timo Huttula; Sami Saraperä; Aki Artimo; Taina Korpiharju; Lauri Äystö; Päivi Fjäder; Timo Assmuth; Kirsi Rosendahl; Taina Nysten
Journal:  Environ Sci Pollut Res Int       Date:  2017-09-29       Impact factor: 4.223

6.  The First Attempt at Non-Linear in Silico Prediction of Sampling Rates for Polar Organic Chemical Integrative Samplers (POCIS).

Authors:  Thomas H Miller; Jose A Baz-Lomba; Christopher Harman; Malcolm J Reid; Stewart F Owen; Nicolas R Bury; Kevin V Thomas; Leon P Barron
Journal:  Environ Sci Technol       Date:  2016-07-18       Impact factor: 9.028

7.  Occurrence of Antibiotics, Antibiotic Resistance Genes and Viral Genomes in Wastewater Effluents and Their Treatment by a Pilot Scale Nanofiltration Unit.

Authors:  Maria Beatriz Cristóvão; Solomon Tela; Andreia Filipa Silva; Micaela Oliveira; Andreia Bento-Silva; Maria Rosário Bronze; Maria Teresa Barreto Crespo; João Goulão Crespo; Mónica Nunes; Vanessa Jorge Pereira
Journal:  Membranes (Basel)       Date:  2020-12-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.