Evaluation of radiation exposure to pediatric trauma patients.

Bryan Tepper1, Jane H Brice, Cherri D Hobgood.   

Abstract

BACKGROUND: Pediatric trauma patients pose a diagnostic challenge to physicians. Computed tomography (CT) imaging identifies life-threatening injuries quickly and efficiently. CT radiation dose in pediatric trauma patients is a concern. STUDY
OBJECTIVES: We evaluated the cumulative effective dose of radiation received by pediatric blunt trauma patients and assessed characteristics of patients and studies received.
METHODS: We retrospectively identified pediatric blunt trauma patients at a Level I trauma center between January 1 and December 31, 2006 utilizing the North Carolina Trauma Registry. We searched the patient radiographic history for images in the 7 days after their trauma event. We calculated cumulative effective radiation dose using dose length product and age coefficients. We collected demographic information including age, sex, mechanism of injury, hospital length of stay, and discharge status.
RESULTS: Seventy-five pediatric blunt trauma patients with available radiographic records were included. The median age was 11.7 years; males comprised 64% of patients; median Injury Severity Score was 13.8; 64% were transfer patients; median number of CT scans during initial evaluation was 3.4 for directly seen patients and two for transferred patients. Mean effective ionizing radiation dose was 11.4 mSv for CT scans performed in the first 24 h. Sixteen percent of admitted patients had CT scans in the subsequent 6 days, with an average additional CT dose of 4 mSv. Average number of plain radiographs was five.
CONCLUSIONS: Pediatric blunt trauma patients receive a major radiation burden in their initial evaluation. Patients who are transferred from an outside facility endure an even higher dose of radiation.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23246000     DOI: 10.1016/j.jemermed.2012.09.035

Source DB:  PubMed          Journal:  J Emerg Med        ISSN: 0736-4679            Impact factor:   1.484


  7 in total

1.  Repeat computed tomography scans after pediatric trauma: results of an institutional effort to minimize radiation exposure.

Authors:  Sandra M Farach; Paul D Danielson; Ernest K Amankwah; Nicole M Chandler
Journal:  Pediatr Surg Int       Date:  2015-08-15       Impact factor: 1.827

2.  Computed tomography-related radiation exposure in children transferred to a Level I pediatric trauma center.

Authors:  Adam S Brinkman; Kara G Gill; Charles M Leys; Ankush Gosain
Journal:  J Trauma Acute Care Surg       Date:  2015-06       Impact factor: 3.313

3.  Boots on the ground: how to influence your local radiology departments to use appropriate CT dose.

Authors:  Thomas L Slovis
Journal:  Pediatr Radiol       Date:  2014-10-11

Review 4.  Ultrasonography for endotracheal tube position in infants and children.

Authors:  Pooja Jaeel; Mansi Sheth; Jimmy Nguyen
Journal:  Eur J Pediatr       Date:  2017-01-13       Impact factor: 3.183

5.  Cumulative doses analysis in young trauma patients: a single-centre experience.

Authors:  Sergio Salerno; Maurizio Marrale; Claudia Geraci; Giuseppe Caruso; Giuseppe Lo Re; Antonio Lo Casto; Massimo Midiri
Journal:  Radiol Med       Date:  2015-09-19       Impact factor: 3.469

6.  Pediatric and adult trauma centers differ in evaluation, treatment, and outcomes for severely injured adolescents.

Authors:  Ashley E Walther; Richard A Falcone; Timothy A Pritts; Dennis J Hanseman; Bryce R H Robinson
Journal:  J Pediatr Surg       Date:  2016-04-12       Impact factor: 2.545

7.  Pediatric Trauma Transfer Imaging Inefficiencies-Opportunities for Improvement with Cloud Technology.

Authors:  Yana Puckett; Alvin To
Journal:  AIMS Public Health       Date:  2016-02-26
  7 in total