Literature DB >> 23245507

Femtosecond laser-assisted small-aperture corneal inlay implantation for corneal compensation of presbyopia: two-year follow-up.

Orang Seyeddain1, Alexander Bachernegg, Wolfgang Riha, Theresa Rückl, Herbert Reitsamer, Günther Grabner, Alois K Dexl.   

Abstract

PURPOSE: To report the 2-year postoperative safety and efficacy outcomes after monocular Kamra corneal inlay (ACI7000PDT) implantation in femtosecond laser-created corneal pockets of emmetropic presbyopic patients to improve near and intermediate vision.
SETTING: University Eye Clinic, Paracelsus Medical University, Salzburg, Austria.
DESIGN: Prospective interventional case series.
METHODS: Patients had corneal inlay implantation in the nondominant eye. Emmetropic presbyopic patients between 45 and 60 years old with an uncorrected distance visual acuity (UDVA) of 20/20 or better in both eyes and without additional ocular pathology were eligible. Contrast sensitivity, visual field examinations, endothelial cell count (ECC), and central corneal thickness (CCT) measurements were assessed preoperatively and 12 and 24 months postoperatively. The UDVA, uncorrected intermediate visual acuity (UIVA), and near visual acuity (UNVA) were assessed preoperatively and 1 day, 1 week, and 1, 3, 6, 9, 12, 18, and 24 months postoperatively. The minimum postoperative follow-up was 24 months.
RESULTS: After 24 months, the mean binocular UNVA improved from 20/50 to 20/25; 20 patients (83%) had a UNVA of 20/25 or better. The mean binocular UIVA was 20/20. The mean UDVA was 20/20 in the surgical eye and 20/16 binocularly after 24 months. Contrast sensitivity under photopic and mesopic conditions remained in the range of the normal population. No patient had detectable central visual field defect. No inlay was explanted. No inflammatory reactions were observed. The ECC and CCT remained stable.
CONCLUSION: The corneal inlay implanted in femtosecond laser-created pockets was effective and safe for the corneal compensation of presbyopia in emmetropic patients after 24 months. FINANCIAL DISCLOSURE: Acufocus Inc., Irvine, California, USA, financially supports the Research Foundation for Promoting Ophthalmology, Salzburg, Austria, as the clinical research center of the University Eye Clinic (Paracelsus Medical University). Dr. Grabner received travel expenses from Acufocus, Inc. Dr. Riha currently also works as a clinical application specialist for Acufocus, Inc. No other author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23245507     DOI: 10.1016/j.jcrs.2012.09.018

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  17 in total

1.  [The KAMRA™ inlay : A realistic approach?]

Authors:  M El-Husseiny; L Daas; A Viestenz; A Langenbucher; B Seitz
Journal:  Ophthalmologe       Date:  2017-04       Impact factor: 1.059

Review 2.  Small-aperture intracorneal inlay implantation in emmetropic presbyopic patients: a systematic review.

Authors:  Inés Pluma-Jaramago; Carlos Rocha-de-Lossada; Rahul Rachwani-Anil; José-María Sánchez-González
Journal:  Eye (Lond)       Date:  2022-03-28       Impact factor: 4.456

Review 3.  Refractive surgery beyond 2020.

Authors:  Marcus Ang; Damien Gatinel; Dan Z Reinstein; Erik Mertens; Jorge L Alió Del Barrio; Jorge L Alió
Journal:  Eye (Lond)       Date:  2020-07-24       Impact factor: 3.775

Review 4.  Implantable inlay devices for presbyopia: the evidence to date.

Authors:  Em Arlt; Em Krall; S Moussa; G Grabner; Ak Dexl
Journal:  Clin Ophthalmol       Date:  2015-01-14

Review 5.  Clinical utility of the KAMRA corneal inlay.

Authors:  Shehzad Anjam Naroo; Paramdeep Singh Bilkhu
Journal:  Clin Ophthalmol       Date:  2016-05-18

6.  Six-month visual outcomes for the correction of presbyopia using a small-aperture corneal inlay: single-site experience.

Authors:  Majid Moshirfar; Tyler S Quist; David F Skanchy; Ryan T Wallace; Steven H Linn; Phillip C Hoopes
Journal:  Clin Ophthalmol       Date:  2016-11-02

7.  Cataract Surgery in Patients with a Previous History of KAMRA Inlay Implantation: A Case Series.

Authors:  Majid Moshirfar; Tyler S Quist; David F Skanchy; Steven H Linn; Jordan Desautels; Phillip C Hoopes
Journal:  Ophthalmol Ther       Date:  2017-04-25

Review 8.  A Review of Presbyopia Treatment with Corneal Inlays.

Authors:  M Amir Moarefi; Shamik Bafna; William Wiley
Journal:  Ophthalmol Ther       Date:  2017-04-07

9.  Vignetting and field of view with the KAMRA corneal inlay.

Authors:  Achim Langenbucher; Susanne Goebels; Nóra Szentmáry; Berthold Seitz; Timo Eppig
Journal:  Biomed Res Int       Date:  2013-11-13       Impact factor: 3.411

10.  Short-term visual result after simultaneous photorefractive keratectomy and small-aperture cornea inlay implantation.

Authors:  Majid Moshirfar; Ryan T Wallace; David F Skanchy; Jordan D Desautels; Steven H Linn; Phillip C Hoopes; Daniel S Durrie
Journal:  Clin Ophthalmol       Date:  2016-11-11
View more