Literature DB >> 23245358

Modified method of haptic externalization of posterior chamber intraocular lens in fibrin glue-assisted intrascleral fixation: no-assistant technique.

Priya Narang1.   

Abstract

A modified technique for externalizing the haptics in the Agarwal method of glued intrascleral fixation of a posterior chamber intraocular lens (IOL) is described. This technique eliminates the role of an assistant in holding the haptic during the entire surgical maneuver and subsequent complications associated with inappropriate handling of the haptic. The technique was used in 45 cases and was reproducible in all cases with no intraoperative complications. This technique is an attempt to make the process of haptic externalization, considered the most technically demanding part of the surgery, more easy and feasible.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23245358     DOI: 10.1016/j.jcrs.2012.11.001

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.

Authors:  Ertuğrul Can; Adem Gül; Hakkı Birinci
Journal:  Int Ophthalmol       Date:  2015-10-06       Impact factor: 2.031

Review 2.  Glued intrascleral haptic fixation of an intraocular lens.

Authors:  Priya Narang; Amar Agarwal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

3.  Commentary: Comprehending haptic exteriorization in intrascleral haptic fixation of an intraocular lens.

Authors:  Priya Narang
Journal:  Indian J Ophthalmol       Date:  2017-08       Impact factor: 1.848

Review 4.  Pre-Descemet's endothelial keratoplasty.

Authors:  Priya Narang; Amar Agarwal
Journal:  Indian J Ophthalmol       Date:  2017-06       Impact factor: 1.848

5.  Clinical outcomes in traumatic pseudophacocele: A rare clinical entity.

Authors:  Priya Narang; Amar Agarwal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

6.  26-G needle-assisted sutureless glueless intrascleral haptic fixation for secondary ciliary sulcus implantation of three-piece polymethylmethacrylate intraocular lens during penetrating keratoplasty.

Authors:  Harinder Singh Sethi; Mayuresh P Naik; Vishnu S Gupta
Journal:  Taiwan J Ophthalmol       Date:  2016-07-16

7.  The "correct shake" for "handshake" in glued intrascleral fixation of intraocular lens.

Authors:  Priya Narang; Amar Agarwal
Journal:  Indian J Ophthalmol       Date:  2016-11       Impact factor: 1.848

  7 in total