Literature DB >> 23243642

Contrast-enhanced ultrasound guided biopsy of superficial toraco-abdominal and neck lesions. Initial experience in 20 patients.

Zeno Sparchez1, Pompilia Radu, Gabriel Kacso, Dan Eniu, Stefan Hica, Mihaela Sparchez.   

Abstract

AIM: In the diagnostic workup of superficial located tumors, percutaneous biopsy plays an important role. However, a successful retrieval of an adequate tissue sample is achievable in only 80-90% of the cases, mainly due to tissue inhomogenities. Contrast-enhanced ultrasound (CEUS) was successfully used to optimize the percutaneous biopsy in several tumors. The aim of our study was to assess the feasibility of CEUS as a direct guiding method for percutaneous biopsy of superficial toraco-abdominal and neck tumors.
MATERIAL AND METHODS: Twenty patients aged 12-75 years with superficial toraco-abdominal and neck masses were studied. CEUS guided biopsy was performed using the contrast harmonic imaging technique with 9 MHz broadband linear transducer (10 cases) or 3.5MHz transducer (10 cases). The needle (18 G Bard coupled on an automatic device Bard Magnum) was directed in arterial phase into the enhanced, perfused areas. The following parameters were recorded: maximal length of the tumor, perfusion pattern, number of passages, length of the specimen, rate of complications.
RESULTS: The mean maximal length of the tumor was 6.95 cm (range 4-10.6 cm). CEUS guided biopsy was technical successful in 100% of patients. The mean number of passages needed to sample a good specimen was 1.6, range 1-3. The mean length of the specimen was 1.18 cm, range 0.8-1.4cm. The perfusion patterns of the tumors in our series were: P1-non-enhancing mass- 11.1 %, P2 peripherally enhancing mass with non-enhancing central area -5.6%, P3 diffusely enhancing mass with scattered non-enhancing areas -77.7 % and P4 completely homogeneously enhancing masses -5.6% of patients. The sensitivity of CEUS guided biopsy in the diagnosis of superficial tumors was 100%. For adenopathies a sub-typing was possible in all cases. There was only one minor hematoma around the punctured tumor in one patient.
CONCLUSIONS: In our series 83% of the tumors had a perfusion pattern (P2 and P3) that may lead to sampling errors in case of US guided biopsy. CEUS guided biopsy of toraco-abdominal and neck tumors is a feasible technique that improves the sensitivity of percutaneous biopsy to 100%.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23243642

Source DB:  PubMed          Journal:  Med Ultrason        ISSN: 1844-4172            Impact factor:   1.611


  3 in total

1.  The feasibility of contrast enhanced ultrasonography (CEUS) in the diagnosis of non-cardiac thoracic disorders of dogs and cats.

Authors:  N Linta; M Baron Toaldo; G Bettini; A Cordella; M Quinci; P Pey; V Galli; M Cipone; A Diana
Journal:  BMC Vet Res       Date:  2017-05-25       Impact factor: 2.741

2.  Multimodal ultrasound imaging of primary thyroid schwannoma: A case report.

Authors:  Hai Na Zhao; Bu Yun Ma; Feng Yan; Yu Lan Peng
Journal:  Medicine (Baltimore)       Date:  2021-04-23       Impact factor: 1.889

Review 3.  Contrast-enhanced ultrasound (CEUS) in abdominal intervention.

Authors:  Dean Y Huang; Gibran T Yusuf; Mohammad Daneshi; Raymond Ramnarine; Annamaria Deganello; Maria E Sellars; Paul S Sidhu
Journal:  Abdom Radiol (NY)       Date:  2018-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.