Literature DB >> 23243035

The effect of lung-size mismatch on mechanical ventilation tidal volumes after bilateral lung transplantation.

Rebecca Dezube1, George J Arnaoutakis, Robert M Reed, Servet Bolukbas, Ashish S Shah, Jonathan B Orens, Roy G Brower, Michael Eberlein.   

Abstract

OBJECTIVES: Mechanical ventilation tidal volumes are usually set according to an estimate of patient size in millilitres (ml) per kilogram (kg) body weight. We describe the relationship between donor-recipient lung-size mismatch and postoperative mechanical ventilation tidal volumes according to recipient- and donor-predicted body weights in a cohort of bilateral lung transplant patients.
METHODS: A most-undersized (10 patients with lowest predicted total lung capacity [pTLC] ratio = pTLC-donor/pTLC-recipient), a most-oversized (10 patients with highest pTLC ratio) and best-matched subset (10 patients with predicted total lung capacity ratio closest to 1.0) were selected within a cohort of 70 patients. All tidal volumes during mechanical ventilation in the first 96 h after bilateral lung transplantation were recorded. Tidal volumes were expressed in ml and ml/kg-recipient-predicted body weights and ml/kg-donor-predicted body weights.
RESULTS: Postoperative absolute tidal volumes (in ml) were comparable between subsets of patients with undersized, matched and oversized allografts (552 ± 103 vs 581 ± 107 vs 582 ± 104 ml), and tidal volumes in ml/kg-recipient-predicted body weights were also similar (8.8 ± 1.4 vs 9.3 ± 1.1 vs 9.8 ± 2.1). However, tidal volumes in ml/kg-donor-predicted body weights revealed significant differences between undersized, matched, and oversized subsets (11.4 ± 3.1 vs 9.4 ± 1.2 vs 8.1 ± 2.1, respectively; P < 0.05). Two patients developed primary graft dysfunction grade 3, both in the undersized subset. Four patients in the undersized group underwent tracheotomy (vs none in matched and one in oversized subset).
CONCLUSIONS: During mechanical ventilation after bilateral lung transplantation, undersized allografts received relatively higher tidal volumes compared with oversized allografts when the tidal volumes were related to donor-predicted body weights.

Entities:  

Mesh:

Year:  2012        PMID: 23243035      PMCID: PMC3568811          DOI: 10.1093/icvts/ivs493

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  9 in total

1.  Potential for detrimental hyperinflation after lung transplantation with application of negative pleural pressure to undersized lung grafts.

Authors:  Benjamin D Kozower; Bryan F Meyers; Anna Maria Ciccone; Tracey J Guthrie; G Alexander Patterson
Journal:  J Thorac Cardiovasc Surg       Date:  2003-02       Impact factor: 5.209

2.  Comparison of pulmonary function test and computed tomography volumetry in living lung donors.

Authors:  Fengshi Chen; Takeshi Kubo; Tsuyoshi Shoji; Takuji Fujinaga; Toru Bando; Hiroshi Date
Journal:  J Heart Lung Transplant       Date:  2011-01-06       Impact factor: 10.247

3.  Mechanical ventilation affects inflammatory mediators in patients undergoing cardiopulmonary bypass for cardiac surgery: a randomized clinical trial.

Authors:  Enrico Zupancich; Domenico Paparella; Franco Turani; Christopher Munch; Alessandra Rossi; Simone Massaccesi; V Marco Ranieri
Journal:  J Thorac Cardiovasc Surg       Date:  2005-08       Impact factor: 5.209

4.  Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome.

Authors:  Roy G Brower; Michael A Matthay; Alan Morris; David Schoenfeld; B Taylor Thompson; Arthur Wheeler
Journal:  N Engl J Med       Date:  2000-05-04       Impact factor: 91.245

5.  Effect of mechanical ventilation on inflammatory mediators in patients with acute respiratory distress syndrome: a randomized controlled trial.

Authors:  V M Ranieri; P M Suter; C Tortorella; R De Tullio; J M Dayer; A Brienza; F Bruno; A S Slutsky
Journal:  JAMA       Date:  1999-07-07       Impact factor: 56.272

6.  Effect of a lung protective strategy for organ donors on eligibility and availability of lungs for transplantation: a randomized controlled trial.

Authors:  Luciana Mascia; Daniela Pasero; Arthur S Slutsky; M Jose Arguis; Maurizio Berardino; Salvatore Grasso; Marina Munari; Silvia Boifava; Giuseppe Cornara; Francesco Della Corte; Nicoletta Vivaldi; Paolo Malacarne; Paolo Del Gaudio; Sergio Livigni; Elisabeth Zavala; Claudia Filippini; Erica L Martin; Pier Paolo Donadio; Ilaria Mastromauro; V Marco Ranieri
Journal:  JAMA       Date:  2010-12-15       Impact factor: 56.272

7.  Ventilator settings as a risk factor for acute respiratory distress syndrome in mechanically ventilated patients.

Authors:  Ognjen Gajic; Fernando Frutos-Vivar; André Esteban; Rolf D Hubmayr; Antonio Anzueto
Journal:  Intensive Care Med       Date:  2005-04-26       Impact factor: 17.440

8.  The effect of lung size mismatch on complications and resource utilization after bilateral lung transplantation.

Authors:  Michael Eberlein; George J Arnaoutakis; Lonny Yarmus; David Feller-Kopman; Rebecca Dezube; Mayy F Chahla; Servet Bolukbas; Robert M Reed; Julia Klesney-Tait; Kalpaj R Parekh; Christian A Merlo; Ashish S Shah; Jonathan B Orens; Roy G Brower
Journal:  J Heart Lung Transplant       Date:  2012-02-09       Impact factor: 10.247

9.  Revision of the 1996 working formulation for the standardization of nomenclature in the diagnosis of lung rejection.

Authors:  Susan Stewart; Michael C Fishbein; Gregory I Snell; Gerald J Berry; Annette Boehler; Margaret M Burke; Alan Glanville; F Kate Gould; Cynthia Magro; Charles C Marboe; Keith D McNeil; Elaine F Reed; Nancy L Reinsmoen; John P Scott; Sean M Studer; Henry D Tazelaar; John L Wallwork; Glen Westall; Martin R Zamora; Adriana Zeevi; Samuel A Yousem
Journal:  J Heart Lung Transplant       Date:  2007-12       Impact factor: 10.247

  9 in total
  14 in total

1.  eComment. Lung size mismatch and graft dysfunction immediately after reperfusion.

Authors:  Michael Eberlein; Servet Bolukbas; Tahuanty Pena; Robert M Reed
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-03

Review 2.  Postoperative management of lung transplant recipients.

Authors:  Christina C Kao; Amit D Parulekar
Journal:  J Thorac Dis       Date:  2019-09       Impact factor: 2.895

Review 3.  Donor to recipient sizing in thoracic organ transplantation.

Authors:  Michael Eberlein; Robert M Reed
Journal:  World J Transplant       Date:  2016-03-24

4.  How to minimise ventilator-induced lung injury in transplanted lungs.

Authors:  Michael Eberlein; Lindsey Barnes; Tahuanty Pena; Robert M Reed
Journal:  Eur J Anaesthesiol       Date:  2016-04       Impact factor: 4.330

Review 5.  Primary graft dysfunction: pathophysiology to guide new preventive therapies.

Authors:  Ciara M Shaver; Lorraine B Ware
Journal:  Expert Rev Respir Med       Date:  2017-01-20       Impact factor: 3.772

6.  Lung size mismatch and primary graft dysfunction after bilateral lung transplantation.

Authors:  Michael Eberlein; Robert M Reed; Servet Bolukbas; Joshua M Diamond; Keith M Wille; Jonathan B Orens; Roy G Brower; Jason D Christie
Journal:  J Heart Lung Transplant       Date:  2014-09-28       Impact factor: 10.247

7.  Donor age and early graft failure after lung transplantation: a cohort study.

Authors:  M R Baldwin; E R Peterson; I Easthausen; I Quintanilla; E Colago; J R Sonett; F D'Ovidio; J Costa; J M Diamond; J D Christie; S M Arcasoy; D J Lederer
Journal:  Am J Transplant       Date:  2013-08-26       Impact factor: 8.086

8.  MECHANICAL VENTILATION FOR THE LUNG TRANSPLANT RECIPIENT.

Authors:  Lindsey Barnes; Robert M Reed; Kalpaj R Parekh; Jay K Bhama; Tahuanty Pena; Srinivasan Rajagopal; Gregory A Schmidt; Julia A Klesney-Tait; Michael Eberlein
Journal:  Curr Pulmonol Rep       Date:  2015-04-26

9.  Lobar lung transplantation from deceased donors: A systematic review.

Authors:  Michael Eberlein; Robert M Reed; Mayy Chahla; Servet Bolukbas; Amy Blevins; Dirk Van Raemdonck; Alessia Stanzi; Ilhan Inci; Silvana Marasco; Norihisa Shigemura; Clemens Aigner; Tobias Deuse
Journal:  World J Transplant       Date:  2017-02-24

10.  Lung protective ventilation based on donor size is associated with a lower risk of severe primary graft dysfunction after lung transplantation.

Authors:  Laneshia K Tague; Bahaa Bedair; Chad Witt; Derek E Byers; Rodrigo Vazquez-Guillamet; Hrishikesh Kulkarni; Jennifer Alexander-Brett; Ruben Nava; Varun Puri; Daniel Kreisel; Elbert P Trulock; Andrew Gelman; Ramsey R Hachem
Journal:  J Heart Lung Transplant       Date:  2021-07-10       Impact factor: 13.569

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.