Literature DB >> 23242148

Salmonella detection in poultry samples. Comparison of two commercial real-time PCR systems with culture methods for the detection of Salmonella spp. in environmental and fecal samples of poultry.

D Sommer1, D Enderlein, A Antakli, H Schönenbrücher, J Slaghuis, T Redmann, M Lierz.   

Abstract

STUDY: The efficiency of two commercial PCR methods based on real-time technology, the foodproof® Salmonella detection system and the BAX® PCR Assay Salmonella system was compared to standardized culture methods (EN ISO 6579:2002 - Annex D) for the detection of Salmonella spp. in poultry samples.
MATERIAL AND METHODS: Four sample matrices (feed, dust, boot swabs, feces) obtained directly from poultry flocks, as well as artificially spiked samples of the same matrices, were used. All samples were tested for Salmonella spp. using culture methods first as the gold standard. In addition samples spiked with Salmonella Enteridis were tested to evaluate the sensitivity of both PCR methods. Furthermore all methods were evaluated in an annual ring-trial of the National Salmonella Reference Laboratory of Germany.
RESULTS: Salmonella detection in the matrices feed, dust and boot swabs were comparable in both PCR systems whereas the results from feces differed markedly. The quality, especially the freshness, of the fecal samples had an influence on the sensitivity of the real-time PCR and the results of the culture methods. In fresh fecal samples an initial spiking level of 100cfu/25g Salmonella Enteritidis was detected. Two-days-dried fecal samples allowed the detection of 14cfu/25g. Both real- time PCR protocols appear to be suitable for the detection of Salmonella spp. in all four matrices. The foodproof® system detected eight samples more to be positive compared to the BAX® system, but had a potential false positive result in one case. In 7-days-dried samples none of the methods was able to detect Salmonella likely through letal cell damage. CLINICAL RELEVANCE: In general the advantage of PCR analyses over the culture method is the reduction of working time from 4-5 days to only 2 days. However, especially for the analysis of fecal samples official validation should be conducted according to the requirement of EN ISO6579:2002 - Annex D.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23242148

Source DB:  PubMed          Journal:  Tierarztl Prax Ausg G Grosstiere Nutztiere        ISSN: 1434-1220            Impact factor:   0.488


  2 in total

1.  Multiplex real-time PCR for detection of Campylobacter, Salmonella, and Shigella.

Authors:  F Barletta; E H Mercado; A Lluque; J Ruiz; T G Cleary; T J Ochoa
Journal:  J Clin Microbiol       Date:  2013-06-12       Impact factor: 5.948

2.  Development of a qPCR for the detection and quantification of Salmonella spp. in sheep feces and tissues.

Authors:  Alysia M Parker; Virginia L Mohler; Alison A Gunn; John K House
Journal:  J Vet Diagn Invest       Date:  2020-08-28       Impact factor: 1.279

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.