Literature DB >> 23241823

A multicenter, randomized, controlled clinical trial of LigaSure small jaw vessel sealing system versus conventional technique in thyroidectomy.

Prakobkiat Hirunwiwatkul1, Sutumma Tungkavivachagul.   

Abstract

The objective of this work was to compare efficacy and adverse effects between vessel sealing system thyroid lobectomy (VSSL) with the new LigaSure™ Small Jaw Instrument and conventional thyroid lobectomy (CTL). This is a multicenter, randomized and controlled study, conducted in the Department of Otolaryngology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Faculty of Medicine, Chulalongkorn University, Bangkok and Division of Otolaryngology, Sukhothai General Hospital, Sukhothai, Thailand. Forty subjects with solitary thyroid nodule planned for thyroid lobectomy were enrolled consecutively in both centers. Intervention was randomized by block randomization into two groups (VSSL, CTL). Primary outcomes were operative time and intraoperative blood loss. Secondary outcomes were postoperative blood loss and recurrent laryngeal nerve paralysis. There was clinically significant less operative time (VSSL/CTL = 62.4 ± 15.9/83.3 ± 16.1 min, p < 0.001) and less intraoperative blood loss (VSSL/CTL = 40.5 ± 19.1/63.3 ± 22.4 mL, p = 0.001) in VSSL group compared with CTL group. There was no significant difference of postoperative blood loss (VSSL/CTL = 58.8 ± 30.6/76.0 ± 36.9 mL, p = 0.116) between both the groups. There was one case of permanent recurrent laryngeal nerve injury found in both groups. VSSL with the new LigaSure™ Small Jaw Instrument was better than conventional technique in terms of shortening operative time. It was also better in reducing intraoperative hemorrhage, but this effect did not exceed clinically significant levels. Postoperative blood loss and recurrent laryngeal nerve injury were not significantly different between both the groups.

Entities:  

Mesh:

Year:  2012        PMID: 23241823     DOI: 10.1007/s00405-012-2289-8

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  18 in total

1.  Comparison of thermal spread after ureteral ligation with the Laparo-Sonic ultrasonic shears and the Ligasure system.

Authors:  Sharon L Goldstein; Kristi L Harold; Alan Lentzner; Brent D Matthews; Kent W Kercher; Ronald F Sing; Broc Pratt; Edward H Lipford; B Todd Heniford
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2002-02       Impact factor: 1.878

2.  Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.

Authors:  Jaime Landman; Kurt Kerbl; Jamil Rehman; Cassio Andreoni; Peter A Humphrey; William Collyer; Ephrem Olweny; Chandru Sundaram; Ralph V Clayman
Journal:  J Urol       Date:  2003-02       Impact factor: 7.450

3.  A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy.

Authors:  Carlos Cordón; Rafael Fajardo; Jaqueline Ramírez; Miguel F Herrera
Journal:  Surgery       Date:  2005-03       Impact factor: 3.982

4.  The use of Ligasure Vessel Sealing System in thyroid surgery.

Authors:  Vassilios A Lachanas; Emmanuel P Prokopakis; Antonios A Mpenakis; Alexander D Karatzanis; George A Velegrakis
Journal:  Otolaryngol Head Neck Surg       Date:  2005-03       Impact factor: 3.497

5.  Thyroid surgery: use of the LigaSure Vessel Sealing System versus conventional knot tying.

Authors:  Tamer Youssef; Tarek Mahdy; Mokhtar Farid; Atif Abdel Latif
Journal:  Int J Surg       Date:  2008-05-23       Impact factor: 6.071

6.  Bipolar thermofusion vessel sealing system (TVS) versus conventional vessel ligation (CVL) in thyroid surgery--results of a prospective study.

Authors:  Pier Francesco Alesina; Thomas Rolfs; Martin K Walz
Journal:  Langenbecks Arch Surg       Date:  2010-02       Impact factor: 3.445

7.  The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery.

Authors:  Allan E Siperstein; Eren Berber; Ebru Morkoyun
Journal:  Arch Surg       Date:  2002-02

8.  Parathyroid function after open thyroidectomy: A prospective randomized study for ligasure precise versus harmonic FOCUS.

Authors:  Gianlorenzo Dionigi; Sam Van Slycke; Stefano Rausei; Luigi Boni; Renzo Dionigi
Journal:  Head Neck       Date:  2012-06-19       Impact factor: 3.147

9.  Usefulness of electrosurgical techniques in thyroid gland surgery.

Authors:  Bartosz W Kowalski; Jacek Bierca; Jan Zmora; Małgorzata Kołodziejczak; Anna Kosim; Mariusz Frączek
Journal:  Pol Przegl Chir       Date:  2012-05

10.  Ligasure vessel sealing system versus conventional vessel ligation in thyroidectomy.

Authors:  U Lepner; T Vaasna
Journal:  Scand J Surg       Date:  2007       Impact factor: 2.360

View more
  15 in total

1.  Effectiveness of the LigaSure Small Jaw Vessel-Sealing System in Hepatic Resection.

Authors:  Miwa Yoshimoto; Kanenori Endo; Takehiko Hanaki; Joji Watanabe; Naruo Tokuyasu; Teruhisa Sakamoto; Soichiro Honjo; Yasuaki Hirooka; Masahide Ikeguchi
Journal:  Yonago Acta Med       Date:  2014-07-30       Impact factor: 1.641

Review 2.  Safety of energy based devices for hemostasis in thyroid surgery.

Authors:  Gianlorenzo Dionigi; Che-Wei Wu; Hoon-Yub Kim; Xiaoli Liu; Renbin Liu; Gregory W Randolph; Angkoon Anuwong
Journal:  Gland Surg       Date:  2016-10

3.  A comparison of the outcome using Ligasure™ small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study.

Authors:  S Coiro; F M Frattaroli; F De Lucia; E Manna; F Fabi; J M Frattaroli; G Pappalardo
Journal:  Langenbecks Arch Surg       Date:  2015-01-13       Impact factor: 3.445

Review 4.  A comparison of surgical outcomes and complications between hemostatic devices for thyroid surgery: a network meta-analysis.

Authors:  Yingwei Luo; Xi Li; Jianwei Dong; Weifeng Sun
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-08-01       Impact factor: 2.503

5.  Efficacy and safety of LigaSure™ small jaw instrument in thyroidectomy: a 1-year prospective observational study.

Authors:  Xiao-Chun Mao; Chao Chen; Ke-Jing Wang
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-03-13       Impact factor: 2.503

6.  Intra- and postoperative complications using LigaSure™ Small Jaw in patients undergoing thyroidectomy: a register-based study.

Authors:  Anne Yoon Krogh Grøndal; Morten Høgsbro; Kasper Pryds; Henrik Baymler Pedersen; Henrik Jacobsen
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-03-10       Impact factor: 2.503

7.  Comparison of skin-sparing mastectomy using LigaSure™ Small Jaw and electrocautery.

Authors:  Young Woo Chang; Hwan Soo Kim; Seung Pil Jung; Sang Uk Woo; Jae Bok Lee; Jeoung Won Bae; Gil Soo Son
Journal:  World J Surg Oncol       Date:  2017-07-14       Impact factor: 2.754

8.  A meta-analysis comparing the outcomes of LigaSure Small Jaw versus clamp-and-tie technique or Harmonic Focus Scalpel in thyroidectomy.

Authors:  Lei Zhang; Namei Li; Xuemei Yang; Jie Chen
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

9.  Comparing postoperative complication of LigaSure Small Jaw instrument with clamp and tie method in thyroidectomy patients: a randomized controlled trial [IRCT2014010516077N1].

Authors:  Ali Ramouz; Seyed Ziaeddin Rasihashemi; Abdolrasoul Safaeiyan; Mahdie Hosseini
Journal:  World J Surg Oncol       Date:  2018-09-21       Impact factor: 2.754

10.  Predisposing factors for seroma formation in patients undergoing thyroidectomy: Cross-sectional study.

Authors:  Ali Ramouz; Seyed Ziaeddin Rasihashemi; Faeze Daghigh; Esmaeil Faraji; Shahin Rouhani
Journal:  Ann Med Surg (Lond)       Date:  2017-09-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.