Literature DB >> 23238557

Poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liner in primary total hip replacement: one-year results of a prospective cohort study.

Yoshio Takatori1, Toru Moro, Morihide Kamogawa, Hiromi Oda, Shuhei Morimoto, Takashige Umeyama, Manabu Minami, Hideharu Sugimoto, Shigeru Nakamura, Tatsuro Karita, Juntaku Kim, Yurie Koyama, Hideya Ito, Hiroshi Kawaguchi, Kozo Nakamura.   

Abstract

To control particle-induced osteolysis in total hip replacement (THR), we developed a new technique to graft poly(2-methacryloyloxyethyl phosphorylcholine) onto the surface of polyethylene liners. A prospective cohort study was conducted to investigate the clinical safety of this novel bearing surface. Between April 2007 and September 2008, we recruited a prospective consecutive series of 80 patients in five participating hospitals. These patients received a cementless THR; a 26-mm-diameter cobalt-chromium-molybdenum alloy ball and a poly(2-methacryloyloxyethyl phosphorylcholine)-grafted cross-linked polyethylene liner were used for the bearing couplings. These individuals were followed a year postoperatively. An evaluation of clinical performance was conducted through an assessment of hip joint function based on the evaluation chart authorized by the Japanese Orthopaedic Association. No patients were lost to follow-up. No adverse events were found to be correlated with the implanted liners. The average hip joint function score improved from 43.2 preoperatively to 91.7 postoperatively at 1 year. There was no implant migration nor periprosthetic osteolysis detected on radiographic analysis. On the basis of our results, we conclude that poly(2-methacryloyloxyethyl phosphorylcholine)-grafted cross-linked polyethylene liners are a safe implant option for hip replacement surgery for short-term clinical use.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23238557     DOI: 10.1007/s10047-012-0681-1

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  14 in total

1.  Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles.

Authors:  H G Willert; H Bertram; G H Buchhorn
Journal:  Clin Orthop Relat Res       Date:  1990-09       Impact factor: 4.176

2.  Failure of carbon fiber-reinforced polyethylene total knee-replacement components. A report of two cases.

Authors:  T M Wright; D J Astion; M Bansal; C M Rimnac; T Green; J N Insall; R P Robinson
Journal:  J Bone Joint Surg Am       Date:  1988-07       Impact factor: 5.284

3.  The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.

Authors:  J Charnley
Journal:  J Bone Joint Surg Br       Date:  1972-02

4.  Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner.

Authors:  B J Livingston; M J Chmell; M Spector; R Poss
Journal:  J Bone Joint Surg Am       Date:  1997-10       Impact factor: 5.284

5.  2006 Frank Stinchfield Award: grafting of biocompatible polymer for longevity of artificial hip joints.

Authors:  Toru Moro; Yoshio Takatori; Kazuhiko Ishihara; Kozo Nakamura; Hiroshi Kawaguchi
Journal:  Clin Orthop Relat Res       Date:  2006-12       Impact factor: 4.176

6.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

7.  Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis.

Authors:  Toru Moro; Yoshio Takatori; Kazuhiko Ishihara; Tomohiro Konno; Yorinobu Takigawa; Tomiharu Matsushita; Ung-Il Chung; Kozo Nakamura; Hiroshi Kawaguchi
Journal:  Nat Mater       Date:  2004-10-24       Impact factor: 43.841

8.  Preclinical biocompatibility assessment of the EVAHEART ventricular assist device: coating comparison and platelet activation.

Authors:  Trevor A Snyder; Hiroyuki Tsukui; Shin'Ichiro Kihara; Takehide Akimoto; Kenneth N Litwak; Marina V Kameneva; Kenji Yamazaki; William R Wagner
Journal:  J Biomed Mater Res A       Date:  2007-04       Impact factor: 4.396

9.  Total hip arthroplasty using proximal porous coating stem with distal sleeve: mid-term outcome.

Authors:  M Saito; K A Takahashi; M Fujioka; K Ueshima; K Sakao; S Inoue; T Kubo
Journal:  J Orthop Surg (Hong Kong)       Date:  2009-04       Impact factor: 1.118

10.  Quality of life following femoral osteotomy and total hip arthroplasty for nontraumatic osteonecrosis of the femoral head.

Authors:  Taisuke Seki; Yukiharu Hasegawa; Tetsuo Masui; Jin Yamaguchi; Toshiya Kanoh; Naoki Ishiguro; Kiyoharu Kawabe
Journal:  J Orthop Sci       Date:  2008-04-08       Impact factor: 1.601

View more
  2 in total

Review 1.  Journal of Artificial Organs 2013: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; E Tatsumi; T Tsukiya; K Matsuda; K Fukunaga; A Kishida; T Masuzawa; G Matsumiya; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2014-02-26       Impact factor: 1.731

2.  Multidirectional wear and impact-to-wear tests of phospholipid-polymer-grafted and vitamin E-blended crosslinked polyethylene: a pilot study.

Authors:  Masayuki Kyomoto; Toru Moro; Yoshio Takatori; Sakae Tanaka; Kazuhiko Ishihara
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.