Literature DB >> 23238217

Inter and intra laboratory concordance of HLA antibody results obtained by single antigen bead based assay.

Manish J Gandhi1, Steven Degoey, Deborah Falbo, Sarah Jenkins, James R Stubbs, Harriet Noreen, David F Lorentzen, Jarhow Lee, Mark Stegall.   

Abstract

Single antigen bead based assays (SAB) to identify antibodies to HLA are marketed as a qualitative test, however often used as a quantitative test as the results provide mean fluorescence intensity (MFI) which is found to correlate with the strength/avidity of the antibody. We studied the between and within laboratory variability in performing the SAB from one manufacturer. Ten samples were tested at four laboratories according to the manufacturer's suggested protocol. Additionally same samples were tested on four consecutive days in one laboratory. All tests were performed using the same lot of beads and secondary antibody. Results were classified as positive at four different MFI cutoffs: 1000, 5000, 8000 and 10,000. MFI values across and within the laboratory were compared in a pair-wise fashion with Pearson's correlations. Overall concordance for Class-I was 97% between laboratories and 98% within laboratory at all cutoffs. Pair-wise Pearson correlation between laboratories was 0.989-0.99, while within laboratory it was 0.998-0.999. For Class-II, overall concordance between and within laboratory was 98%. Pair-wise Pearson correlation between laboratories was 0.991-0.997, while within laboratory it was 0.997-0.999. There is good correlation between laboratories and within laboratory using the same manufacturer, same lot and same protocol while performing SAB.
Copyright © 2012 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23238217     DOI: 10.1016/j.humimm.2012.12.003

Source DB:  PubMed          Journal:  Hum Immunol        ISSN: 0198-8859            Impact factor:   2.850


  4 in total

Review 1.  Methodological aspects of anti-human leukocyte antigen antibody analysis in solid organ transplantation.

Authors:  Andrew L Lobashevsky
Journal:  World J Transplant       Date:  2014-09-24

Review 2.  Interpreting Anti-HLA Antibody Testing Data: A Practical Guide for Physicians.

Authors:  Carrie A Schinstock; Manish J Gandhi; Mark D Stegall
Journal:  Transplantation       Date:  2016-08       Impact factor: 4.939

3.  Interlaboratory Comparison of the Results of Lifecodes LSA Class I and Class II Single Antigen Kits for Human Leukocyte Antigen Antibody Detection.

Authors:  Eun-Jee Oh; Hyewon Park; Kyoung Un Park; Eun-Suk Kang; Hyon-Suk Kim; Eun Young Song
Journal:  Ann Lab Med       Date:  2015-04-01       Impact factor: 3.464

4.  Single antigen flow beads for identification of human leukocyte antigen antibody specificities in hypersensitized patients with chronic renal failure.

Authors:  Mustafa Soyöz; Tülay Kılıçaslan-Ayna; Aslı Özkızılcık-Koçyiğit; Derya Güleç; İbrahim Pirim
Journal:  Cent Eur J Immunol       Date:  2016-01-20       Impact factor: 2.085

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.