Literature DB >> 23237459

In situ cell-matrix mechanics in tendon fascicles and seeded collagen gels: implications for the multiscale design of biomaterials.

Neil A Duncan1, Sabina B Bruehlmann, Christopher J Hunter, Xinxin Shao, Elizabeth J Kelly.   

Abstract

Designing biomaterials to mimic and function within the complex mechanobiological conditions of connective tissues requires a detailed understanding of the micromechanical environment of the cell. The objective of our study was to measure the in situ cell-matrix strains from applied tension in both tendon fascicles and cell-seeded type I collagen scaffolds using laser scanning confocal microscopy techniques. Tendon fascicles and collagen gels were fluorescently labelled to simultaneously visualise the extracellular matrix and cell nuclei under applied tensile strains of 5%. There were significant differences observed in the micromechanics at the cell-matrix scale suggesting that the type I collagen scaffold did not replicate the pattern of native tendon strains. In particular, although the overall in situ tensile strains in the matrix were quite similar (∼2.5%) between the tendon fascicles and the collagen scaffolds, there were significant differences at the cell-matrix boundary with visible shear across cell nuclei of >1 μm measured in native tendon which was not observed at all in the collagen scaffolds. Similarly, there was significant non-uniformity of intercellular strains with relative sliding observed between cell rows in tendon which again was not observed in the collagen scaffolds where the strain environment was much more uniform. If the native micromechanical environment is not replicated in biomaterial scaffolds, then the cells may receive incorrect or mixed mechanical signals which could affect their biosynthetic response to mechanical load in tissue engineering applications. This study highlights the importance of considering the microscale mechanics in the design of biomaterial scaffolds and the need to incorporate such features in computational models of connective tissues.

Mesh:

Substances:

Year:  2012        PMID: 23237459     DOI: 10.1080/10255842.2012.742075

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  4 in total

1.  Macro- to microscale strain transfer in fibrous tissues is heterogeneous and tissue-specific.

Authors:  Woojin M Han; Su-Jin Heo; Tristan P Driscoll; Lachlan J Smith; Robert L Mauck; Dawn M Elliott
Journal:  Biophys J       Date:  2013-08-06       Impact factor: 4.033

2.  Impact of cellular microenvironment and mechanical perturbation on calcium signalling in meniscus fibrochondrocytes.

Authors:  W M Han; S-J Heo; T P Driscoll; M E Boggs; R L Duncan; R L Mauck; D M Elliott
Journal:  Eur Cell Mater       Date:  2014-06-08       Impact factor: 3.942

3.  Interfibrillar shear stress is the loading mechanism of collagen fibrils in tendon.

Authors:  Spencer E Szczesny; Dawn M Elliott
Journal:  Acta Biomater       Date:  2014-02-12       Impact factor: 8.947

4.  DTAF dye concentrations commonly used to measure microscale deformations in biological tissues alter tissue mechanics.

Authors:  Spencer E Szczesny; Rachel S Edelstein; Dawn M Elliott
Journal:  PLoS One       Date:  2014-06-10       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.