Literature DB >> 23233175

Comparison of the Exeter Trauma Stem and the Thompson hemiarthroplasty for intracapsular hip fractures.

Amit S C Bidwai1, Keith M Willett.   

Abstract

A planned change in the prosthesis used for hip hemiarthroplasty in one orthopaedic trauma unit from the Thompson prosthesis to the Exeter Trauma Stem (ETS) was studied. We completed a prospective continuous audit study comparing outcomes for patients undergoing the procedure before (766 patients) and after (388 patients) the change of practice. Outcomes measured included surgical complications (including infection or dislocation) and a postoperative radiographic review. There was no difference in the incidence of surgical complications between the groups, and no difference in ratings given to postoperative radiographs between both groups. In theory, the ETS may be easier to revise, should this be required in future, but in other respects the devices are comparable.

Entities:  

Mesh:

Year:  2012        PMID: 23233175     DOI: 10.5301/HIP.2012.10100

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  5 in total

1.  Cemented Thompson's hemiarthroplasty in patients with intracapsular neck of femur fractures: survival analysis of 1,670 procedures.

Authors:  S K Khan; S S Jameson; A Sims; J A'Court; M R Reed; A Rangan; S D Muller
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-27

2.  The Dislocated Hip Hemiarthroplasty: Current Concepts of Etiological factors and Management.

Authors:  Carl Jones; Nikolai Briffa; Joshua Jacob; Richard Hargrove
Journal:  Open Orthop J       Date:  2017-10-31

3.  The World Hip Trauma Evaluation Study 3: Hemiarthroplasty Evaluation by Multicentre Investigation - WHITE 3: HEMI - An Abridged Protocol.

Authors:  A L Sims; N Parsons; J Achten; X L Griffin; M L Costa; M R Reed
Journal:  Bone Joint Res       Date:  2016-01       Impact factor: 5.853

4.  Thompson hemiarthroplasty versus modular unipolar implants for patients requiring hemiarthroplasty of the hip: A systematic review of the evidence.

Authors:  A L Sims; A J Farrier; M R Reed; T A Sheldon
Journal:  Bone Joint Res       Date:  2017-08       Impact factor: 5.853

5.  A randomized controlled trial comparing the Thompson hemiarthroplasty with the Exeter polished tapered stem and Unitrax modular head in the treatment of displaced intracapsular fractures of the hip: the WHiTE 3: HEMI Trial.

Authors:  A L Sims; N Parsons; J Achten; X L Griffin; M L Costa; M R Reed
Journal:  Bone Joint J       Date:  2018-03-01       Impact factor: 5.082

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.