Literature DB >> 2323257

Clinical and electrophysiologic correlates of sinus node dysfunction after orthotopic heart transplantation. Observations in 42 patients.

G Heinz1, T Ohner, G Laufer, S Gasic, A Laczkovics.   

Abstract

We assessed incidence and course of postoperative SN dysfunction in 42 cardiac transplant recipients. RHY, HR and CSNRT were compared in distinguishing between persistent (9 of 42 patients) and transient (11 of 42) SN dysfunction. Persistent SN dysfunction was distinguished by a significantly lower HR (day 14: 46.2 +/- 12 vs 67 +/- 19 bpm; day 21: 40.3 +/- 21 vs 70.8 +/- 16 bpm; p less than 0.05, respectively) and by RHY: postoperative AS (3 of 42) was found only in patients whose SN dysfunction persisted while patients with SR but prolonged CSNRT more often had transient impairment (6 of 42 vs 2 of 42); CSNRT, in contrast, is unlikely to be useful in distinguishing between transient and persistent SN dysfunction since exceptionally long CSNRTs (11,340 ms. 12,080 ms) occurred in patients with both types. Ischemic times were significantly longer in patients with transient impairment when compared with the group with normal SN function (155.1 +/- 36 vs 109.2 +/- 36 min, p less than 0.05) but did not differ significantly in patients with persistent SN dysfunction (124.8 +/- 32 min). Thus, (1) SN dysfunction after cardiac transplantation is common but most often transient; (2) RHY and HR are adequate follow-up parameters and best predictors of long-term SN function; (3) SN dysfunction after transplantation has important clinical implications given the unreliability of lower pacemakers to take over in 3 patients; (4) transient SN dysfunction is related to duration of ischemia during hypothermic preservation whereas pathogenesis of persistent SN dysfunction remains to be elucidated.

Entities:  

Mesh:

Year:  1990        PMID: 2323257     DOI: 10.1378/chest.97.4.890

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  6 in total

1.  The electrophysiology of cardiac allograft rejection: independent effects of rejection and perioperative ischemia on the sinus node recovery phenomenon after cardiac transplantation.

Authors:  G Heinz; M Hirschl; G Laufer; P Buxbaum; H Gössinger; P Siostrzonek; S Gasic; A Laczkovics
Journal:  Basic Res Cardiol       Date:  1992 Nov-Dec       Impact factor: 17.165

2.  Nonpharmacologic validation of the intrinsic heart rate in cardiac transplant recipients.

Authors:  J S Strobel; A E Epstein; R C Bourge; J K Kirklin; G N Kay
Journal:  J Interv Card Electrophysiol       Date:  1999-03       Impact factor: 1.900

3.  Permanent pacemaker implantation after cardiac transplantation: extra cost of a conservative policy.

Authors:  N D Holt; G Parry; M M Tynan; J H Dark; J M McComb
Journal:  Heart       Date:  1996-11       Impact factor: 5.994

4.  Permanent pacemaker use after cardiac transplantation: completing the audit cycle.

Authors:  N D Holt; M M Tynan; C D Scott; G Parry; J H Dark; J M McComb
Journal:  Heart       Date:  1996-11       Impact factor: 5.994

5.  Optimal pacing modes after cardiac transplantation: is synchronisation of recipient and donor atria beneficial?

Authors:  G Parry; K Malbut; J H Dark; R S Bexton
Journal:  Br Heart J       Date:  1992-08

6.  Permanent pacing after cardiac transplantation.

Authors:  C D Scott; J M McComb; J H Dark; R S Bexton
Journal:  Br Heart J       Date:  1993-05
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.