Final 5-year results of the TAXUS ATLAS, TAXUS ATLAS Small Vessel, and TAXUS ATLAS Long Lesion clinical trials of the TAXUS Liberté paclitaxel-eluting stent in de-novo coronary artery lesions.

John A Ormiston1, O'Shaughnessy Charles, Tift Mann, Jack J Hall, Thomas McGarry, Louis A Cannon, Mark W I Webster, Gregory J Mishkel, Paul L Underwood, Keith D Dawkins.   

Abstract

OBJECTIVE: To report the final, cumulative, 5-year outcomes from the TAXUS ATLAS program, which studied the use of the TAXUS Liberté paclitaxel-eluting stent in de-novo coronary artery lesions.
METHODS: TAXUS ATLAS Workhorse, Small Vessel, and Long Lesion are nonrandomized studies comparing TAXUS Liberté (N=871), TAXUS Liberté 2.25 mm (N=261), and TAXUS Liberté 38 mm (N=150) stents, respectively, with case-matched TAXUS Express historical controls.
RESULTS: In the unadjusted analysis, TAXUS Liberté showed comparable 5-year rates of major adverse cardiac events (27.1% TAXUS Express vs. 26.2% TAXUS Liberté, P=0.70) in workhorse lesions and greater 5-year cumulative freedom from target lesion revascularization (78.4 vs. 87.3%, P=0.03) in small vessels. In addition, a lower periprocedural myocardial infarction rate (MI, 4.1 vs. 0.0%; P=0.01) was observed in long lesions versus TAXUS Express. After propensity score adjustment, no statistically significant effect of TAXUS Liberté on the 5-year rates of TLR in small vessels (17.9 vs. 13.3%, P=0.36) or MI in long lesions (9.1 vs. 7.0%, P=0.53) was found, although the rates remained numerically lower with TAXUS Liberté.
CONCLUSION: Cumulative 5-year results of the TAXUS ATLAS studies suggest that the TAXUS Liberté stent provides similar safety and effectiveness in workhorse lesions, and may provide lower revascularization rates in small vessels and lower periprocedural MI rates in long lesions compared with the TAXUS Express stent, although no statistically significant differences were found following propensity adjustment.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23232250     DOI: 10.1097/MCA.0b013e32835b3932

Source DB:  PubMed          Journal:  Coron Artery Dis        ISSN: 0954-6928            Impact factor:   1.439