Literature DB >> 23231900

Laser-induced breakdown spectroscopy (LIBS) of heavy metal ions at the sub-parts per million level in water.

Yonghoon Lee1, Se-Woung Oh, Song-Hee Han.   

Abstract

We report a simple sub parts per million (sub-ppm) detection method for heavy metals in water by laser-induced breakdown spectroscopy (LIBS). Filter papers were used as the substrates for both transforming aqueous solutions to solid samples and for pre-concentrating dissolved heavy metal ions. The amount of sample uptake was 1.2 g by soaking a filter paper. This provides limit-of-detection (LOD) values of 2.7 and 0.36 ppm for Pb and Cr, respectively. The LODs could be improved remarkably by pre-concentrating the heavy metal ions. When a 40 g sample solution was evaporated on a filter paper, the LODs of 75 and 18 parts per billion (ppb) were obtained for Pb and Cr, respectively. Moreover, by either increasing the evaporated amount of sample solution or applying an argon gas flow, further improvement of the LODs was found to be very promising. The LIBS spectra of tap water were recorded using the pre-concentration method and are discussed in comparison with the results from inductively coupled plasma atomic emission spectroscopy (ICP-AES). We could observe strong emission lines of Ca, Mg, K, Cu, and Sr in the tap water, of which concentrations were determined to be 6.3, 1.3, 1.1, 0.64, and 0.046 ppm, respectively, by ICP-AES. Our method shows promise as a fast, reliable, water-quality monitoring tool for heavy-metal concentrations as well as for hardness.

Entities:  

Year:  2012        PMID: 23231900     DOI: 10.1366/12-06639R

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  4 in total

Review 1.  Laser-induced breakdown spectroscopy application in environmental monitoring of water quality: a review.

Authors:  Xiaodong Yu; Yang Li; Xiaofeng Gu; Jiming Bao; Huizhong Yang; Li Sun
Journal:  Environ Monit Assess       Date:  2014-09-26       Impact factor: 2.513

2.  Rapid determination of trace cadmium in drinking water using laser-induced breakdown spectroscopy coupled with chelating resin enrichment.

Authors:  Hongwu Tian; Leizi Jiao; Daming Dong
Journal:  Sci Rep       Date:  2019-07-18       Impact factor: 4.379

3.  Toward a Selective Analysis of Heavy Metal Salts in Aqueous Media with a Fluorescent Probe Array.

Authors:  Andrey G Melnikov; Denis A Bykov; Alexey S Varezhnikov; Victor V Sysoev; Gennady V Melnikov
Journal:  Sensors (Basel)       Date:  2022-02-14       Impact factor: 3.576

4.  Half-life determination of inorganic-organic hybrid nanomaterials in mice using laser-induced breakdown spectroscopy.

Authors:  Yanwu Chu; Zhanjie Zhang; Qianyuan He; Feng Chen; Ziqian Sheng; Deng Zhang; Honglin Jin; Fagang Jiang; Lianbo Guo
Journal:  J Adv Res       Date:  2020-05-16       Impact factor: 10.479

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.