Literature DB >> 23231592

Effect of myopia on ganglion cell complex and peripapillary retinal nerve fibre layer measurements: a Fourier-domain optical coherence tomography study of young Chinese persons.

Zhennan Zhao1, Chunhui Jiang.   

Abstract

BACKGROUND: To investigate the change of the ganglion cell complex and peripapillary retinal nerve fibre layer under different refractive conditions, as measured by optical coherence tomography.
DESIGN: Cross-sectional observational study. PARTICIPANTS: A total of 107 eyes from 107 subjects were studied.
METHODS: Ganglion cell complex and retinal nerve fibre layer were studied by a spectral-domain system. Their relationship against spherical equivalents and axial length was studied. MAIN OUTCOME MEASURES: The thickness of ganglion cell complex and retinal nerve fibre layer at different area and under different refractive conditions as measurements by optical coherence tomography.
RESULTS: The average, superior and inferior macular ganglion cell complex thickness was significantly associated with both spherical equivalents (all P < 0.05) and axial length (all P < 0.05). Peripapillary retinal nerve fibre layer thicknesses from the superior, inferior and temporal quadrants were associated with both spherical equivalents (all P < 0.01), axial length (all P < 0.05) and ganglion cell complex thickness (all P < 0.001), except for the nasal part. However, if the retinal nerve fibre layer thickness was studied in sections, then some parts of the upper and lower temporal part showed no correlation with either spherical equivalents or axial length (all P < 0.05).
CONCLUSIONS: The thicknesses of the ganglion cell complex and most of the peripapillary retinal nerve fibre layer were correlated with refraction and axial length. Therefore, when using these for clinical purposes, attention must be paid to the refractive state of the patient.
© 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  ganglion cell complex; myopia; optical coherence tomography; retinal nerve fibre

Mesh:

Year:  2013        PMID: 23231592     DOI: 10.1111/ceo.12045

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  12 in total

1.  Comparison of macular ganglion cell complex thickness to total retinal thickness ratio between Hungarian and Japanese eyes.

Authors:  Yoshiyuki Kita; Farzaneh Naghizadeh; Ritsuko Kita; Goji Tomita; Gábor Holló
Journal:  Jpn J Ophthalmol       Date:  2013-08-27       Impact factor: 2.447

2.  Influence of axial length on ganglion cell complex (GCC) thickness and on GCC thickness to retinal thickness ratios in young adults.

Authors:  Asuka Takeyama; Yoshiyuki Kita; Ritsuko Kita; Goji Tomita
Journal:  Jpn J Ophthalmol       Date:  2013-11-19       Impact factor: 2.447

Review 3.  Macular imaging with optical coherence tomography in glaucoma.

Authors:  Vahid Mohammadzadeh; Nima Fatehi; Adeleh Yarmohammadi; Ji Woong Lee; Farideh Sharifipour; Ramin Daneshvar; Joseph Caprioli; Kouros Nouri-Mahdavi
Journal:  Surv Ophthalmol       Date:  2020-03-19       Impact factor: 6.048

4.  Comparison of peripapillary retinal nerve fiber layer thickness between myopia severity groups and controls.

Authors:  Evelyn Li Min Tai; Jiunn Loong Ling; Eng Hui Gan; Hussein Adil; Wan-Hitam Wan-Hazabbah
Journal:  Int J Ophthalmol       Date:  2018-02-18       Impact factor: 1.779

5.  Interocular Symmetry of Macular Ganglion Cell Complex Thickness in Young Chinese Subjects.

Authors:  Minwen Zhou; Bing Lu; Jingke Zhao; Qiu Wang; Pengfei Zhang; Xiaodong Sun
Journal:  PLoS One       Date:  2016-07-25       Impact factor: 3.240

6.  Ganglion cell-inner plexiform layer and retinal nerve fiber layer thickness according to myopia and optic disc area: a quantitative and three-dimensional analysis.

Authors:  Sam Seo; Chong Eun Lee; Jae Hoon Jeong; Ki Ho Park; Dong Myung Kim; Jin Wook Jeoung
Journal:  BMC Ophthalmol       Date:  2017-03-11       Impact factor: 2.209

7.  Age-Related Physiologic Thinning Rate of the Retinal Nerve Fiber Layer in Different Levels of Myopia.

Authors:  Daun Jeong; Kyung Rim Sung; Youn Hye Jo; Sung-Cheol Yun
Journal:  J Ophthalmol       Date:  2020-01-20       Impact factor: 1.909

8.  Swept-source optical coherence tomography imaging of macular retinal and choroidal structures in healthy eyes.

Authors:  Jiawei Wang; Xinbo Gao; Wenbin Huang; Wei Wang; Sida Chen; Shaolin Du; Xingyi Li; Xiulan Zhang
Journal:  BMC Ophthalmol       Date:  2015-09-17       Impact factor: 2.209

9.  Influence of Clinical Factors and Magnification Correction on Normal Thickness Profiles of Macular Retinal Layers Using Optical Coherence Tomography.

Authors:  Tomomi Higashide; Shinji Ohkubo; Masanori Hangai; Yasuki Ito; Noriaki Shimada; Kyoko Ohno-Matsui; Hiroko Terasaki; Kazuhisa Sugiyama; Paul Chew; Kenneth K W Li; Nagahisa Yoshimura
Journal:  PLoS One       Date:  2016-01-27       Impact factor: 3.240

10.  Association of high myopia with peripapillary retinal nerve fiber layer in patients with hypertension.

Authors:  Min-Woo Lee; Hyung-Bin Lim; Hyung-Moon Koo; Young-Hoon Lee; Jung-Yeul Kim
Journal:  PLoS One       Date:  2021-08-13       Impact factor: 3.240

View more