Three-dimensional fit of lithium disilicate partial crowns in vitro.

Oliver Schaefer1, Harald Kuepper, Bernd W Sigusch, Geoffrey A Thompson, Arthur F Hefti, Arndt Guentsch.   

Abstract

OBJECTIVES: A novel three-dimensional scanning technique was used to investigate the effects a one-step and a two-step impression methods can have on the three-dimensional fit of ceramic partial crowns.
METHODS: An acrylic model of a mandibular first molar was prepared to receive a partial coverage all-ceramic crown (mesio-occlusal-distal inlay preparation with reduction of all cusps and rounded shoulder finish line of buccal wall). Type IV plaster replicates were cast based on one-step single viscosity (OS/SV), one-step dual viscosity (OS/DV), and two-step dual viscosity (TS/DV) impressions. Five partial crowns were fabricated per impression method using hot-pressed lithium disilicate ceramics. Then, preparation and restorations were digitized using a non-contact, white-light scanner featuring self-calibrating optics (overall measurement uncertainty of <5μm). Data were entered into quality inspection software which superimposed the records (best-fit-algorithm), calculated fit-discrepancies for every pixel, and colour-coded the results to aid visualization. Furthermore, mean quadratic deviations (RMS) were computed and analyzed statistically with a 1-way ANOVA. Scheffé's procedure was applied for multiple comparisons (α=0.05).
RESULTS: Mean RMS-values for marginal (internal) surfaces were: OS/SV 70 (20)μm, OS/DV 78 (34)μm, and TS/DV 107 (52)μm. Differences among impression techniques were statistically significant at p=0.006 (0.001). Qualitatively, occlusal ridges and preparation finish lines were over contoured, whereas inner occlusal boxes and the proximal-occlusal isthmus were under contoured.
CONCLUSIONS: OS/SV and OS/DV impressions resulted in statistically significantly smaller marginal and internal discrepancies than the two-step technique. CLINICAL SIGNIFICANCE: Marginal and internal fit of hot-pressed lithium disilicate partial crowns depended on the employed impression technique. One-step impressions are preferred over two-step techniques in many day-to-day clinical situations, especially for the fabrication of partial coverage crown restorations.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23228498     DOI: 10.1016/j.jdent.2012.11.014

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  8 in total

1.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

2.  White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions.

Authors:  Jin-Hun Jeon; Kyung-Tak Lee; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

3.  Influence of Teeth Preparation Finishing on the Adaptation of Lithium Disilicate Crowns.

Authors:  Bruna Salamoni Sinhori; Mauro Amaral Caldeira de Andrada; Guilherme Carpena Lopes; Sylvio Monteiro Junior; Luiz Narciso Baratieri
Journal:  Int J Biomater       Date:  2017-03-23

4.  Accuracy and reproducibility of 3D digital tooth preparations made by gypsum materials of various colors.

Authors:  Fa-Bing Tan; Chao Wang; Hong-Wei Dai; Yu-Bo Fan; Jin-Lin Song
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

5.  In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies.

Authors:  Çise Özal; Mutahhar Ulusoy
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

6.  Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study.

Authors:  Mohamed Fattouh; Laila Mohamed Mohamed Kenawi; Hesham Fattouh
Journal:  Imaging Sci Dent       Date:  2021-08-11

7.  Reliability and validity of intraoral and extraoral scanners.

Authors:  Helder B Jacob; Graydon D Wyatt; Peter H Buschang
Journal:  Prog Orthod       Date:  2015-10-27       Impact factor: 2.750

8.  Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas.

Authors:  Estefanía Aranda Yus; Josep Maria Anglada Cantarell; Antonio Miñarro Alonso
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.