Literature DB >> 23228308

A variational approach to image registration in dynamic contrast-enhanced MRI of the human kidney.

Andreas D Merrem1, Frank G Zöllner, Marcel Reich, Arvid Lundervold, Jarle Rorvik, Lothar R Schad.   

Abstract

Kidney function can be accessed by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measurements which yield spatially resolved maps of physiological parameters like perfusion or filtration. The motion of the kidneys during the scan is a dominant limitation of the measurement quality, and image registration is necessary for accurate quantification. We analyzed the feasibility of applying an algorithm, originally developed for multimodal registration, to kidney perfusion time series. The algorithm uses a variational calculation scheme to align the images. In four out of five data sets, kidney motion could be reduced to below the spatial resolution of the images of 1.6mm while preserving the enhancement pattern of kidney perfusion. Fitting a pharmacokinetic model to the data showed an average reduction of the Akaike fit error of 10% for the registered data, suggesting more stable parameters. We conclude that this image registration algorithm is feasible for correcting kidney motion in renal DCE-MRI.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23228308     DOI: 10.1016/j.mri.2012.10.011

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  7 in total

1.  Estimating nonrigid motion from inconsistent intensity with robust shape features.

Authors:  Wenyang Liu; Dan Ruan
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

2.  Shape-based motion correction in dynamic contrast-enhanced MRI for quantitative assessment of renal function.

Authors:  Wenyang Liu; Kyunghyun Sung; Dan Ruan
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

Review 3.  [Quantitative perfusion imaging in magnetic resonance imaging].

Authors:  F G Zöllner; T Gaa; F Zimmer; M M Ong; P Riffel; D Hausmann; S O Schoenberg; M Weis
Journal:  Radiologe       Date:  2016-02       Impact factor: 0.635

4.  Modified dixon-based renal dynamic contrast-enhanced MRI facilitates automated registration and perfusion analysis.

Authors:  Anneloes de Boer; Tim Leiner; Eva E Vink; Peter J Blankestijn; Cornelis A T van den Berg
Journal:  Magn Reson Med       Date:  2017-11-13       Impact factor: 4.668

Review 5.  Image registration in dynamic renal MRI-current status and prospects.

Authors:  Frank G Zöllner; Amira Šerifović-Trbalić; Gordian Kabelitz; Marek Kociński; Andrzej Materka; Peter Rogelj
Journal:  MAGMA       Date:  2019-10-09       Impact factor: 2.310

6.  Synthetic Arterial Spin Labeling MRI of the Kidneys for Evaluation of Data Processing Pipeline.

Authors:  Irène Brumer; Dominik F Bauer; Lothar R Schad; Frank G Zöllner
Journal:  Diagnostics (Basel)       Date:  2022-07-31

7.  Motion correction of free-breathing magnetic resonance renography using model-driven registration.

Authors:  Dimitra Flouri; Daniel Lesnic; Constantina Chrysochou; Jehill Parikh; Peter Thelwall; Neil Sheerin; Philip A Kalra; David L Buckley; Steven P Sourbron
Journal:  MAGMA       Date:  2021-06-23       Impact factor: 2.310

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.