Literature DB >> 23228080

Evaluating of small intracranial aneurysms by 64-detector CT Angiography: a comparison with 3-dimensional rotation DSA or surgical findings.

He Zhang1, Chang Hou, Zhi Zhou, Hao Zhang, Gen Zhou, Gui Zhang.   

Abstract

BACKGROUND AND
PURPOSE: The diagnostic performance of 64-detector computed tomographic angiography (CTA) for detection of small intracranial aneurysms (SIAs) was evaluated.
METHODS: In this prospective study, 112 consecutive patients underwent 64-detector CTA before volume-rendering rotation digital subtraction angiography (VR-RDSA) or surgery. VR-RDSA or intraoperative findings or both were used as the gold standards. The accuracy, sensitivity, specificity, and positive predictive values (PPV) and negative predictive values (NPV), as measures to detect or rule out SIAs, were determined by patient-based and aneurysm size-based evaluations.
RESULTS: The reference standard methods revealed 84 small aneurysms in 71 patients. The results of patient-based 64-detector CTA evaluation for SIAs were: accuracy, 98.2%; sensitivity, 98.6%; specificity, 97.6%; PPV, 98.6%; and NPV, 97.6%. The aneurysm-based evaluation results were: accuracy, 96.8%; sensitivity, 97.6%; specificity, 95.1%; PPV, 97.6%; and NPV, 95.1%. Two false-positive and two false-negative findings for aneurysms <3 mm in size occurred in the 64-detector CTA analysis.
CONCLUSION: The diagnostic performance of 64-detector CTA did not improve much compared with 16-detector CTA for detecting SIAs, especially for very small aneurysms. VR-RDSA is still necessary for patients with a history of subarachnoid hemorrhage if the CTA findings are negative.
Copyright © 2012 by the American Society of Neuroimaging.

Entities:  

Keywords:  3-dimensional rotation angiography; Small intracranial aneurysms; computed tomographic angiography

Mesh:

Year:  2012        PMID: 23228080     DOI: 10.1111/j.1552-6569.2012.00747.x

Source DB:  PubMed          Journal:  J Neuroimaging        ISSN: 1051-2284            Impact factor:   2.486


  3 in total

1.  Intra- and inter-observer variability in intracranial aneurysm segmentation: comparison between CT angiography (semi-automated segmentation software stroke VCAR) and digital subtraction angiography (3D rotational angiography).

Authors:  F D'Argento; A Pedicelli; C Ciardi; E Leone; M Scarabello; A Infante; A Alexandre; E Lozupone; I Valente; C Colosimo
Journal:  Radiol Med       Date:  2020-09-09       Impact factor: 3.469

2.  Intraoperative 3D rotational angiography: an emergency tool for the diagnosis of intracranial aneurysms.

Authors:  Thomas Westermaier; Nadine Willner; Giles H Vince; Thomas Linsenmann; Ralf-Ingo Ernestus; Christian Stetter
Journal:  Emerg Radiol       Date:  2014-07-03

3.  3D rotational fluoroscopy for intraoperative clip control in patients with intracranial aneurysms--assessment of feasibility and image quality.

Authors:  Thomas Westermaier; Thomas Linsenmann; György A Homola; Mario Loehr; Christian Stetter; Nadine Willner; Ralf-Ingo Ernestus; Laszlo Solymosi; Giles H Vince
Journal:  BMC Med Imaging       Date:  2016-04-19       Impact factor: 1.930

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.