Literature DB >> 23224576

Quality assurance in immunoassay performance--comparison of different enzyme immunoassays for the determination of caffeine in consumer products.

Julia Grandke1, Lidia Oberleitner, Ute Resch-Genger, Leif-Alexander Garbe, Rudolf J Schneider.   

Abstract

Enzyme immunoassays with optical detection are amongst the most widely used bioanalytical tools. We defined seven parameters for the quality assessment of immunoassays that were addressed in a systematic study of direct and indirect immunoassays, using the enzymes horseradish peroxidase (HRP) and alkaline phosphatase (AP), the chromogenic substrates 3,3',5,5'-tetramethylbenzidine (TMB) and para-nitrophenyl phosphate, and the fluorescent substrates 3-(4-hydroxyphenyl)propionic acid and 4-methylumbelliferyl phosphate. The same monoclonal antibody against caffeine was used throughout the study. The four quality parameters regarding the standard curve were the test midpoint (sensitivity), the measurement range, the relative dynamic range of the signal, and the goodness of fit of the adjusted four-parameter logistic function. All HRP immunoassays showed a higher sensitivity compared to the AP assays. On the basis of all four criteria, it was established that the direct assay format is superior to the indirect format, the immunoassay using HRP TMB fulfilling all requirements best. In a second step, caffeine concentrations in 24 beverage and cosmetics samples were determined and three more quality parameters were assessed with this application. The direct HRP TMB assay showed one of the best intra- and inter-plate precisions and the best accuracy, defined by the correlation of results with those from the chosen reference method liquid chromatography tandem mass spectrometry (LC-MS/MS). Considering all criteria, HRP TMB seems to be the enzyme substrate system of choice preferably used in the direct assay format.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23224576     DOI: 10.1007/s00216-012-6596-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  Visual paper-based sensor for the highly sensitive detection of caffeine in food and biological matrix based on CdTe-nano ZnTPyP combined with chemometrics.

Authors:  Hengye Chen; Rui Liu; Xiaoming Guo; Gaoqiong Deng; Lu Xu; Lei Zhang; Wei Lan; Chunsong Zhou; Yuanbin She; Haiyan Fu
Journal:  Mikrochim Acta       Date:  2021-01-06       Impact factor: 5.833

2.  Site-specific scFv labelling with invertase via Sortase A mechanism as a platform for antibody-antigen detection using the personal glucose meter.

Authors:  Nur Faezee Ismail; Theam Soon Lim
Journal:  Sci Rep       Date:  2016-01-19       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.