Literature DB >> 23223636

Quantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.

Paaladinesh Thavendiranathan1, Shizhen Liu, Saurabh Datta, Sanjay Rajagopalan, Thomas Ryan, Stephen R Igo, Matthew S Jackson, Stephen H Little, Nathalie De Michelis, Mani A Vannan.   

Abstract

BACKGROUND: The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. METHODS AND
RESULTS: Using an in vitro model of MR, the effective regurgitant orifice area and regurgitant volume (RVol) were measured by the PISA technique using 2-dimensional (2D) and 3D (automated true 3D PISA) transthoracic echocardiography. The mean anatomic regurgitant orifice area (0.35±0.10 cm(2)) was underestimated to a greater degree by the 2D (0.12±0.05 cm(2)) than the 3D method (0.25±0.10 cm(2); P<0.001 for both). Compared with the flowmeter (40±14 mL), the RVol by 2D PISA (20±19 mL) was underestimated (P<0.001), but the 3D peak (43±16 mL) and integrated PISA-based (38±14 mL) RVol were comparable (P>0.05 for both). In patients (n=30, functional MR), 3D effective regurgitant orifice area correlated well with cardiac magnetic resonance imaging RVol r=0.84 and regurgitant fraction r=0.80. Compared with cardiac magnetic resonance imaging RVol (33±22 mL), the integrated PISA RVol (34±26 mL; P=0.42) was not significantly different; however, the peak PISA RVol was higher (48±27 mL; P<0.001). In addition, RVol calculated as the difference in automated mitral and aortic stroke volumes by real-time 3D volume color flow Doppler echocardiography was not significantly different from cardiac magnetic resonance imaging (34±21 versus 33±22 mL; P=0.33).
CONCLUSIONS: Automated real-time 3D volume color flow Doppler based 3D PISA is more accurate than the 2D PISA method to quantify MR. In patients with functional MR, the 3D RVol by integrated PISA is more accurate than a peak PISA technique. Automated 3D stroke volume measurement can also be used as an adjunctive method to quantify MR severity.

Entities:  

Mesh:

Year:  2012        PMID: 23223636     DOI: 10.1161/CIRCIMAGING.112.980383

Source DB:  PubMed          Journal:  Circ Cardiovasc Imaging        ISSN: 1941-9651            Impact factor:   7.792


  24 in total

Review 1.  Peri-procedural imaging for transcatheter mitral valve replacement.

Authors:  Navin Natarajan; Parag Patel; Thomas Bartel; Samir Kapadia; Jose Navia; William Stewart; E Murat Tuzcu; Paul Schoenhagen
Journal:  Cardiovasc Diagn Ther       Date:  2016-04

Review 2.  Cardiovascular imaging: a glimpse into the future.

Authors:  William A Zoghbi
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

3.  Comparative quantification of primary mitral regurgitation by computer modeling and simulated echocardiography.

Authors:  Wenbin Mao; Andrés Caballero; Rebecca T Hahn; Wei Sun
Journal:  Am J Physiol Heart Circ Physiol       Date:  2020-01-10       Impact factor: 4.733

4.  Anticipating the Vicious Circle of Postinfarction Mitral Regurgitation: Imaging Insights.

Authors:  Jacob P Dal-Bianco; Philipp E Bartko; Robert A Levine
Journal:  Circ Cardiovasc Imaging       Date:  2016-07       Impact factor: 7.792

5.  Usefulness of 3D-PISA as compared to guideline endorsed parameters for mitral regurgitation quantification.

Authors:  Frank P Schmidt; Theresa Gniewosz; Alexander Jabs; Thomas Münzel; Ulrich Hink; Patrizio Lancellotti; Ralph-Stephan von Bardeleben
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-19       Impact factor: 2.357

Review 6.  What Does 3D Echocardiography Add to 2D Echocardiography in the Assessment of Mitral Regurgitation?

Authors:  Tadafumi Sugimoto; Raluca Dulgheru; Stella Marchetta; Federica Ilardi; Laura Contu; Yun Yun Go; Patrizio Lancellotti
Journal:  Curr Cardiol Rep       Date:  2017-08-24       Impact factor: 2.931

7.  Quantification of mitral valve regurgitation by 2D and 3D echocardiography compared with cardiac magnetic resonance a systematic review and meta-analysis.

Authors:  Victor Sköldborg; Per Lav Madsen; Morten Dalsgaard; Jawdat Abdulla
Journal:  Int J Cardiovasc Imaging       Date:  2019-10-29       Impact factor: 2.357

Review 8.  Guide to functional mitral regurgitation: a contemporary review.

Authors:  Ramya Vajapey; Deborah Kwon
Journal:  Cardiovasc Diagn Ther       Date:  2021-06

Review 9.  Current Clinical Applications of Three-Dimensional Echocardiography: When the Technique Makes the Difference.

Authors:  Elena Surkova; Denisa Muraru; Patrizia Aruta; Gabriella Romeo; Jurate Bidviene; Diana Cherata; Luigi P Badano
Journal:  Curr Cardiol Rep       Date:  2016-11       Impact factor: 2.931

10.  Regurgitation Hemodynamics Alone Cause Mitral Valve Remodeling Characteristic of Clinical Disease States In Vitro.

Authors:  Patrick S Connell; Anam F Azimuddin; Seulgi E Kim; Fernando Ramirez; Matthew S Jackson; Stephen H Little; K Jane Grande-Allen
Journal:  Ann Biomed Eng       Date:  2015-07-30       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.