Literature DB >> 23223515

Tackling reproducibility in microcantilever biosensors: a statistical approach for sensitive and specific end-point detection of immunoreactions.

Priscila M Kosaka1, Javier Tamayo, José J Ruz, Sara Puertas, Ester Polo, Valeria Grazu, Jesús M de la Fuente, Montserrat Calleja.   

Abstract

In the last decade, microcantilever biosensors have shown enormous potential for highly sensitive label-free detection of nucleic acid and proteins. Despite the enormous advances, the promise of applications of this technology in the biomedical field has been frustrated because of its low reproducibility. Here we tackle the reproducibility issue in microcantilever biosensors and provide the guidelines to minimize the deviations in the biosensor response between different assays. We use as a model system the label-free end-point detection of horseradish peroxidase. We choose the end-point detection mode because of its suitability for implementation in the clinical field that requires simplicity and point-of-care capability. Our study comprises the analysis of 1012 cantilevers with different antibody surface densities, two blocking strategies based on polyethylene-glycol (PEG) and bovine serum albumin (BSA) and stringent controls. The study reveals that the performance of the assay critically depends on both antibody surface density and blocking strategies. We find that the optimal conditions involve antibody surface densities near but below saturation and blocking with PEG. We find that the surface stress induced by the antibody-antigen binding is significantly correlated with the surface stress generated during the antibody attachment and blocking steps. The statistical correlation is harnessed to identify immobilization failure or success, and thus enhancing the specificity and sensitivity of the assay. This procedure enables achieving rates of true positives and true negatives of 90% and 91% respectively. The detection limit is of 10 ng mL(-1) (250 pM) that is similar to the detection limit obtained in our enzyme-linked immunosorbent assay (ELISA) and at least two orders of magnitude smaller than that achieved with well-established label-free biosensors such as a quartz crystal microbalance (QCM) and surface plasmon resonance (SPR) sensor.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23223515     DOI: 10.1039/c2an36192b

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  9 in total

1.  Cancer biomarkers: Detected twice for good measure.

Authors:  Giovanni Longo
Journal:  Nat Nanotechnol       Date:  2014-12       Impact factor: 39.213

2.  Detection of cancer biomarkers in serum using a hybrid mechanical and optoplasmonic nanosensor.

Authors:  P M Kosaka; V Pini; J J Ruz; R A da Silva; M U González; D Ramos; M Calleja; J Tamayo
Journal:  Nat Nanotechnol       Date:  2014-11-02       Impact factor: 39.213

3.  Functionalized Polymer Microgel Particles Enable Customizable Production of Label-Free Sensor Arrays.

Authors:  Mark A Lifson; Jared A Carter; Benjamin L Miller
Journal:  Anal Chem       Date:  2015-07-15       Impact factor: 6.986

Review 4.  Role of plasmonics in detection of deadliest viruses: a review.

Authors:  Foozieh Sohrabi; Sajede Saeidifard; Masih Ghasemi; Tannaz Asadishad; Seyedeh Mehri Hamidi; Seyed Masoud Hosseini
Journal:  Eur Phys J Plus       Date:  2021-06-20       Impact factor: 3.911

Review 5.  Hybrid integrated label-free chemical and biological sensors.

Authors:  Simin Mehrabani; Ashley J Maker; Andrea M Armani
Journal:  Sensors (Basel)       Date:  2014-03-26       Impact factor: 3.576

6.  Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection.

Authors:  Priscila M Kosaka; Valerio Pini; Montserrat Calleja; Javier Tamayo
Journal:  PLoS One       Date:  2017-02-15       Impact factor: 3.240

7.  Detection of Cardiovascular CRP Protein Biomarker Using a Novel Nanofibrous Substrate.

Authors:  Isaac Macwan; Ashish Aphale; Prathamesh Bhagvath; Shalini Prasad; Prabir Patra
Journal:  Biosensors (Basel)       Date:  2020-06-24

8.  Lab-on-chip microscope platform for electro-manipulation of a dense microtubules network.

Authors:  Daniel Havelka; Ilia Zhernov; Michal Teplan; Zdeněk Lánský; Djamel Eddine Chafai; Michal Cifra
Journal:  Sci Rep       Date:  2022-02-14       Impact factor: 4.379

9.  Spatially Multiplexed Micro-Spectrophotometry in Bright Field Mode for Thin Film Characterization.

Authors:  Valerio Pini; Priscila M Kosaka; Jose J Ruz; Oscar Malvar; Mario Encinar; Javier Tamayo; Montserrat Calleja
Journal:  Sensors (Basel)       Date:  2016-06-21       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.