Il Choi1, Hyunjoo Lee, Joungdu Shin, Hyunook Kim.
Abstract
Sewer odors have been a concern to citizens of the Metropolitan Seoul region, which has installed combined sewer systems (CSSs) in 86% of its area. Although a variety of odorants are released from sewers, volatile sulfur compounds (VSCs) have been recognized as major ones. A number of technologies have been proposed to monitor or control odors from sewers. One of the most popular strategies adopted for the control of sewage odor is by applying a commercial odor-reducing agent into the sewer. In this study, the effectiveness of five different commercial odor-reducing agents (i.e., an odor masking agent, an alkaline solution, two microbial agents, and a chemical oxidant) was evaluated by continuously monitoring VSCs released from the sewer with an on-line total reduced sulfur (TRS) analyzer before and after each agent was sprayed into CSSs at five different locations of the city. In short, when the effectiveness of odor treatment was tested in the sewer system using five commercial odor reducing treatments, only the chemical oxidant was good enough to reduce the odor in terms of TRS levels measured before and after the application (p < 0.01).Entities:
Mesh:
Substances:
Year: 2012 PMID: 23223148 PMCID: PMC3571816 DOI: 10.3390/s121216892
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Characteristics of odor reducing agent used in study.
| Characteristic and specification | Phytoncide extracted from woody plants Alkaline | Alkaline solution with Ca, K, Mg, Na, Si, | Munizyme (US product). Bacta-Pur (Canadian product) Activated microorganism | Biomass mixed with natural ingredients | 0.2% NaOCl |
| Working principle | Emission of forest smell to mask bad odor | Increasing wastewater pH to prevent H2S or fatty acids from releasing from sewer | Biodegradation of odorants | Biodegradation of odorants in sewage | Oxidation of odorants |
| Method of spraying | Spray into the sewer by a dispenser attached to the side wall under the manhole cover | Sporadic spray of the solution | Bacta-Pur: spray via a dosing machine Munizyme: spray via a dosing machine | Spray in the headspace of sewer pipes | Spray in the headspace of the sewers |
| Quantity sprayed | 76 mL·d−1 per manhole; the night time of 8 h excluded | 16.7 L·h−1 | Munizyme: 42 mL·h−1 Bacta-Pur: 42 mL·h−1 | 50 mL·h−1 | 3 L·h−1 |
Figure 1.Study sites in Seoul.
Figure 2.Example calibration curve for on-line TRS analyzer against standard H2S gas.
Figure 3.Odor dilution vs. TRS concentration from the sewers in the study sites.
Figure 4.Time profiles of TRS measured at Districts-ONE–FOUR before and after application of Agents-(A–D).
Results of odor and odorants measurement at Districts A, B, C, D and E.
| ONE | Before | 370 (550) | 0.6 (0.1) | 7,500 (13,000) | 185 (310) | 8 (11) | 0.1 (0.1) |
| After | 410 (290) | 0.6 (0.3) | 5,000 (4,900) | 200 (200) | 4 (4) | 1.5 (2.4) | |
| TWO | Before | 90 (20) | 0.3 (0.2) | 150 (19) | 25 (4) | 3 (0.6) | 0.5 (0.1) |
| After | 100 (50) | 0.7 (0.1) | 175 (125) | 50 (30) | 4 (2.5) | 0.8 (0.5) | |
| THREE | Before | 20 (6) | 0.2 (0.1) | 20 (32) | 2.2 (4) | 0.1 (0.2) | 0.1 (0.1) |
| After | 40 (8) | 0.4 (0.3) | 65 (30) | 7.3 (4) | 0.5 (0.8) | 0.1 (0.1) | |
| FOUR | Before | 60 (24) | 0.5 (0.2) | 360 (530) | 7 (10) | 0.6 (1.0) | ND |
| After | 40 (24) | 1.0 (0.1) | 220 (330) | 7 (8) | 1.5 (0.7) | 0.1 (0.1) | |
| FIVE | Before | 6,000 (4,600) | 6 (0.1) | 25,000 (10,000) | 34 (14) | ND (-) | ND (-) |
| After | 300 (140) | 5.6 (0.2) | 2,000 (960) | ND (-) | ND (-) | ND (-) | |
Concentration contents: average (standard deviation);
N.D.: not detected.
Wastewater characteristics before and after treatment with odor-reducing agents at 5 districts.
| Before | 180 | 7.1 | 120 | 18 | 10 | |
| After | 220 | 7.1 | 80 | 17 | 21 | |
| Before | 250 | 7.6 | 80 | 10 | 10 | |
| After | 190 | 7.8 | 90 | 16 | 14 | |
| Before | 220 | 8.4 | 130 | 53 | 9.6 | |
| After | 420 | 7.5 | 240 | 27 | 14.1 | |
| Before | 260 | 8.1 | 135 | 200 | 9.4 | |
| After | 290 | 8.3 | 120 | 170 | 13 | |
| Before | 250 | 6.9 | 170 | 9.4 | 23.5 | |
| A
| 160 | 8.9 | 160 | 13 | 12.5 | |
Figure 5.Time profiles of TRS measured at District-FIVE before and after application of Agent-E.