Histomorphometric and radiographical changes after lumbar implantation of the PEEK nonfusion interspinous device in the BB.4S rat model.

Thomas Barz1, Jörn Lange, Markus Melloh, Lukas P Staub, Harry R Merk, Ingrid Klöting, Niels Follak.   

Abstract

STUDY
DESIGN: An experimental animal study.
OBJECTIVE: To investigate histomorphometric and radiographical changes in the BB.4S rat model after PEEK (polyetheretherketone) nonfusion interspinous device implantation. SUMMARY OF BACKGROUND DATA: Clinical effectiveness of the PEEK nonfusion spine implant Wallis (Abbott, Bordeaux, France; now Zimmer, Warsaw, IN) is well documented. However, there is a lack of evidence on the long-term effects of this implant on bone, in particular its influence on structural changes of bone elements of the lumbar spine.
METHODS: Twenty-four male BB.4S rats aged 11 weeks underwent surgery for implantation of a PEEK nonfusion interspinous device or for a sham procedure in 3 groups of 8 animals each: (1) implantation at level L4-L5; (2) implantation at level L5-L6; and (3) sham surgery. Eleven weeks postoperatively osteolyses at the implant-bone interface were measured via radiograph, bone mineral density of vertebral bodies was analyzed using osteodensitometry, and bone mineral content as well as resorption of the spinous processes were examined by histomorphometry. RESULTS.: Resorption of the spinous processes at the site of the interspinous implant was found in all treated segments. There was no significant difference in either bone density of vertebral bodies or histomorphometric structure of the spinous processes between adjacent vertebral bodies, between treated and untreated segments and between groups.
CONCLUSION: These findings indicate that resorption of spinous processes because of a result of implant loosening, inhibit the targeted load redistribution through the PEEK nonfusion interspinous device in the lumbar spinal segment of the rat. This leads to reduced long-term stability of the implant in the animal model. These results suggest that PEEK nonfusion interspinous devices like the Wallis implants may have time-limited effects and should only be used for specified indications.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23222648     DOI: 10.1097/BRS.0b013e318280c710

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  3 in total

1.  Interspinous posterior devices: What is the real surgical indication?

Authors:  Alessandro Landi
Journal:  World J Clin Cases       Date:  2014-09-16       Impact factor: 1.337

Review 2.  Safe clinical use of carbon nanotubes as innovative biomaterials.

Authors:  Naoto Saito; Hisao Haniu; Yuki Usui; Kaoru Aoki; Kazuo Hara; Seiji Takanashi; Masayuki Shimizu; Nobuyo Narita; Masanori Okamoto; Shinsuke Kobayashi; Hiroki Nomura; Hiroyuki Kato; Naoyuki Nishimura; Seiichi Taruta; Morinobu Endo
Journal:  Chem Rev       Date:  2014-04-10       Impact factor: 60.622

3.  Interspinous process stabilization with Rocker via unilateral approach versus X-Stop via bilateral approach for lumbar spinal stenosis: a comparative study.

Authors:  Weimin Huang; Zhengqi Chang; Jingtao Zhang; Ruoxian Song; Xiuchun Yu
Journal:  BMC Musculoskelet Disord       Date:  2015-11-01       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.