Literature DB >> 23221300

On the validity of 3D polymer gel dosimetry: I. reproducibility study.

Jan Vandecasteele1, Yves De Deene.   

Abstract

The intra- and inter-batch accuracy and precision of MRI (polyacrylamide gelatin gel fabricated at atmospheric conditions) polymer gel dosimeters are assessed in full 3D. In the intra-batch study, eight spherical flasks were filled with the same polymer gel along with a set of test tubes that served as calibration phantoms. In the inter-batch study, the eight spherical flasks were filled with different batches of gel. For each spherical phantom, a separate set of calibration phantoms was used. The spherical phantoms were irradiated using a three-field coplanar beam configuration in a very reproducible manner. The calibration phantoms were irradiated to known doses to obtain a dose-R₂ calibration plot which was applied on the corresponding R₂ maps of all spherical phantoms on an individual basis. The intra-batch study showed high dosimetric precision (3.1%) notwithstanding poor accuracy (mean dose discrepancies up to 13.0%). In the inter-batch study, a similar dosimetric precision (4.3%) and accuracy (mean dose discrepancies up to 13.7%) were found. The poor dosimetric accuracy was attributed to a systematic fault that was related to the calibration method. Therefore, the dose maps were renormalized using an independent ion chamber dose measurement. It is illustrated that with this renormalization, excellent agreement between the gel measured and TPS calculated 3D dose maps is achievable: 97% and 99% of the pixels meet the 3%/3 mm criteria for the intra- and inter-batch experiments, respectively. However renormalization will result in significant dose deviations inside a realistically sized anthropomorphic phantom as will be shown in a concurrent paper.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23221300     DOI: 10.1088/0031-9155/58/1/19

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  3D dosimetric validation of ultrasound-guided radiotherapy with a dynamically deformable abdominal phantom.

Authors:  Charles K Matrosic; Wesley Culberson; Andrew Shepard; Sydney Jupitz; Bryan Bednarz
Journal:  Phys Med       Date:  2021-04-23       Impact factor: 2.685

2.  Radiological properties of nanocomposite Fricke gel dosimeters for heavy ion beams.

Authors:  Takuya Maeyama; Nobuhisa Fukunishi; Kenichi L Ishikawa; Kazuaki Fukasaku; Shigekazu Fukuda
Journal:  J Radiat Res       Date:  2016-03-10       Impact factor: 2.724

3.  Basic Properties of a New Polymer Gel for 3D-Dosimetry at High Dose-Rates Typical for FFF Irradiation Based on Dithiothreitol and Methacrylic Acid (MAGADIT): Sensitivity, Range, Reproducibility, Accuracy, Dose Rate Effect and Impact of Oxygen Scavenger.

Authors:  Muzafar Khan; Gerd Heilemann; Wolfgang Lechner; Dietmar Georg; Andreas Georg Berg
Journal:  Polymers (Basel)       Date:  2019-10-19       Impact factor: 4.329

Review 4.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.