| Literature DB >> 23221148 |
D Sánchez-Parcerisa1, A Gemmel, O Jäkel, E Rietzel, K Parodi.
Abstract
Previous calculations of the water-to-air stopping power ratio (s(w,)(air)) for carbon ion beams did not involve tracking of delta ray electrons, even though previous calculations with protons predict an effect up to 1%. We investigate the effect of the delta ray production threshold in s(w,)(air) calculations and propose an empirical expression which takes into account the effect of the delta ray threshold as well as the uncertainty in the mean ionization potentials (I-values) of air and water. The formula is derived from the results of Monte Carlo calculations using the most up-to-date experimental data for I-values and a delta ray production threshold of 10 keV. It allows us to reduce the standard uncertainty in s(w,)(air) below 0.8%, instead of the current 2% given in international protocols, which results in a reduction of the overall uncertainty for absolute dosimetry based on air-filled ionization chambers.Entities:
Mesh:
Substances:
Year: 2012 PMID: 23221148 DOI: 10.1088/0031-9155/58/1/145
Source DB: PubMed Journal: Phys Med Biol ISSN: 0031-9155 Impact factor: 3.609