Airflow distribution with manual hyperinflation as assessed through gamma camera imaging: a crossover randomised trial.

H van Aswegen1, A van Aswegen, H Du Raan, R Du Toit, M Spruyt, R Nel, M Maleka.   

Abstract

OBJECTIVES: Manual hyperinflation (MHI) has been shown to improve lung compliance, reduce airway resistance, and enhance secretion removal and peak expiratory flow. The aims of this study were to investigate whether there is a difference in airflow distribution through patients' lungs when using the Laerdal and Mapleson-C circuits at a set level of positive end-expiratory pressure (PEEP), and to establish whether differences in lung compliance and haemodynamic status exist when patients are treated with both these MHI circuits.
DESIGN: Crossover randomised controlled trial.
SETTING: Adult multidisciplinary intensive care unit (ICU) at an academic hospital. PARTICIPANTS: Fifteen adult patients were recruited and served as their own controls. INTERVENTION: In the Nuclear Medicine Department, MHI with PEEP 7.5 cmH(2)O was performed in the supine position (Day 1) with either Laerdal or Mapleson-C circuits, in a random order, while technetium-99m (Tc-99m) aerosol was administered and images were taken with a gamma camera. Changes in heart rate (HR), mean arterial pressure (MAP) and dynamic lung compliance (C(D)) were documented at baseline, immediately after return to ICU, and 10, 20 and 30 minutes after return to ICU. The alternative circuit was used on Day 2.
RESULTS: Tc-99m deposition was greater in the right lung field (62% and 63% for Laerdal and Mapleson-C circuits, respectively) than the left lung field (38% and 37%, respectively) for all patients, and least deposition occurred in the left lower segments (6% and 6%, respectively). No differences in Tc-99m deposition in the lungs, HR, MAP or C(D) were noted between the two MHI circuits.
CONCLUSION: Airflow distribution through patients' lungs was similar when the Laerdal and Mapleson-C MHI circuits were compared using a set level of PEEP in the supine position.
Copyright © 2012 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23219638     DOI: 10.1016/j.physio.2012.05.007

Source DB:  PubMed          Journal:  Physiotherapy        ISSN: 0031-9406            Impact factor:   3.358


  3 in total

Review 1.  [Physiotherapy interventions in the ICU : Outcome-relevant measurement parameters].

Authors:  E Zeiser
Journal:  Med Klin Intensivmed Notfmed       Date:  2017-01-23       Impact factor: 0.840

Review 2.  Aerosolised micro and nanoparticle: formulation and delivery method for lung imaging.

Authors:  Miftakul Munir; Herlan Setiawan; Rohadi Awaludin; Vicky L Kett
Journal:  Clin Transl Imaging       Date:  2022-09-29

3.  Outcome measures for manual lung hyperinflation: not there yet!

Authors:  George Ntoumenopoulos
Journal:  Crit Care       Date:  2012-11-08       Impact factor: 9.097

  3 in total