Literature DB >> 23219389

Reactor performance in terms of COD and nitrogen removal and bacterial community structure of a three-stage rotating bioelectrochemical contactor.

Rassil R Sayess1, Pascal E Saikaly, Mutasem El-Fadel, Dong Li, Lucy Semerjian.   

Abstract

Integrating microbial fuel cell (MFC) into rotating biological contactor (RBC) creates an opportunity for enhanced removal of COD and nitrogen coupled with energy generation from wastewater. In this study, a three-stage rotating bioelectrochemical contactor (referred to as RBC-MFC unit) integrating MFC with RBC technology was constructed for simultaneous removal of carbonaceous and nitrogenous compounds and electricity generation from a synthetic medium containing acetate and ammonium. The performance of the RBC-MFC unit was compared to a control reactor (referred to as RBC unit) that was operated under the same conditions but without current generation (i.e. open-circuit mode). The effect of hydraulic loading rate (HLR) and COD/N ratio on the performance of the two units was investigated. At low (3.05 gCOD g⁻¹N) and high COD/N ratio (6.64 gCOD g⁻¹N), both units achieved almost similar COD and ammonia-nitrogen removal. However, the RBC-MFC unit achieved significantly higher denitrification and nitrogen removal compared to the RBC unit indicating improved denitrification at the cathode due to current flow. The average voltage under 1000 Ω external resistance ranged between 0.03 and 0.30 V and between 0.02 and 0.21 V for stages 1 and 2 of the RBC-MFC unit. Pyrosequencing analysis of bacterial 16S rRNA gene revealed high bacterial diversity at the anode and cathode of both units. Genera that play a role in nitrification (Nitrospira; Nitrosomonas), denitrification (Comamonas; Thauera) and electricity generation (Geobacter) were identified at the electrodes. Geobacter was only detected on the anode of the RBC-MFC unit. Nitrifiers and denitrifiers were more abundant in the RBC-MFC unit compared to the RBC unit and were largely present on the cathode of both units suggesting that most of the nitrogen removal occurred at the cathode.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23219389     DOI: 10.1016/j.watres.2012.11.023

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

1.  Advanced low carbon-to-nitrogen ratio wastewater treatment by electrochemical and biological coupling process.

Authors:  Shihai Deng; Desheng Li; Xue Yang; Shanbin Zhu; Wei Xing
Journal:  Environ Sci Pollut Res Int       Date:  2015-11-13       Impact factor: 4.223

2.  Identification of microbial communities in open and closed circuit bioelectrochemical MBRs by high-throughput 454 pyrosequencing.

Authors:  Jian Huang; Zhiwei Wang; Chaowei Zhu; Jinxing Ma; Xingran Zhang; Zhichao Wu
Journal:  PLoS One       Date:  2014-04-04       Impact factor: 3.240

3.  Response Surface Methodology for Optimization of Rotating Biological Contactor Combined with External Membrane Filtration for Wastewater Treatment.

Authors:  Sharjeel Waqas; Noorfidza Yub Harun; Muhammad Roil Bilad; Taufik Samsuri; Nik Abdul Hadi Md Nordin; Norazanita Shamsuddin; Asep Bayu Dani Nandiyanto; Nurul Huda; Jumardi Roslan
Journal:  Membranes (Basel)       Date:  2022-02-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.