Literature DB >> 23218725

Design and validation of GCH System 1.0 which measures the weight-bearing exerted on forearm crutches during aided gait.

Gema Chamorro Moriana1, Jesús Rebollo Roldán, José Jesús Jiménez Rejano, Raquel Chillón Martínez, Carmen Suárez Serrano.   

Abstract

Normally, when the patient's functional recovery involves partial weight-bearing aided walking using forearm crutches, it is not possible to control the amount of weight-bearing objectively that the individuals carry out and its progression. This leads to significant errors in accuracy and, consequently, complications and after effects in pathologies. To compensate for this deficiency, we have set out to design and validate a measurement system and a computerized record of the loads exerted on Canadian crutches in aided walking as well as incorporating a mechanism for acoustic and visual biofeedback that will inform the subject if said charges are correct, so that they are able correct their errors and avoid problems in their recovery. We analyzed the validity and reliability of the system through a concordance study with the AMTI OR6-7-2000 force plate, extensively validated previously, while finding a correlation coefficient of 0.99 with a significance (p<0.001). We have designed and developed a measurement system with a computerized record, analysis and wireless graphical display of real-time data, incorporating a mechanism for acoustic and visual biofeedback to measure the loads exerted on forearm crutches during aided walking. The device, called "GCH System 1.0" is a reliable and valid instrument.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23218725     DOI: 10.1016/j.gaitpost.2012.09.018

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  7 in total

1.  Reliability and Validity Study of the Chamorro Assisted Gait Scale for People with Sprained Ankles, Walking with Forearm Crutches.

Authors:  Gema Chamorro-Moriana; Carmen Ridao-Fernández; Joaquín Ojeda; Marisa Benítez-Lugo; José Luis Sevillano
Journal:  PLoS One       Date:  2016-05-11       Impact factor: 3.240

Review 2.  Technology-Based Feedback and Its Efficacy in Improving Gait Parameters in Patients with Abnormal Gait: A Systematic Review.

Authors:  Gema Chamorro-Moriana; Antonio José Moreno; José Luis Sevillano
Journal:  Sensors (Basel)       Date:  2018-01-06       Impact factor: 3.576

3.  Influence of the load exerted over a forearm crutch in spatiotemporal step parameters during assisted gait: pilot study.

Authors:  Carmen Ridao-Fernández; Gema Chamorro-Moriana; Joaquín Ojeda
Journal:  Biomed Eng Online       Date:  2018-07-18       Impact factor: 2.819

4.  Versatile GCH Control Software for Correction of Loads Applied to Forearm Crutches During Gait Recovery Through Technological Feedback: Development and Implementation Study.

Authors:  Gema Chamorro-Moriana; Jose Luis Sevillano; V Perez-Cabezas
Journal:  J Med Internet Res       Date:  2021-09-22       Impact factor: 5.428

5.  A Compact Forearm Crutch Based on Force Sensors for Aided Gait: Reliability and Validity.

Authors:  Gema Chamorro-Moriana; José Luis Sevillano; Carmen Ridao-Fernández
Journal:  Sensors (Basel)       Date:  2016-06-21       Impact factor: 3.576

6.  Observational Gait Assessment Scales in Patients with Walking Disorders: Systematic Review.

Authors:  Carmen Ridao-Fernández; Elena Pinero-Pinto; Gema Chamorro-Moriana
Journal:  Biomed Res Int       Date:  2019-10-31       Impact factor: 3.411

7.  Load Auditory Feedback Boosts Crutch Usage in Subjects With Central Nervous System Lesions: A Pilot Study.

Authors:  Federica Tamburella; Matteo Lorusso; Nevio Luigi Tagliamonte; Francesca Bentivoglio; Alessandra Bigioni; Iolanda Pisotta; Matteo Lancini; Simone Pasinetti; Marco Ghidelli; Marcella Masciullo; Vincenzo Maria Saraceni; Marco Molinari
Journal:  Front Neurol       Date:  2021-07-06       Impact factor: 4.003

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.