Literature DB >> 23218626

Novel image-matching software for postoperative evaluation after TKA.

Katsumasa Tei1, Kazunari Ishida, Tomoyuki Matsumoto, Seiji Kubo, Hiroshi Sasaki, Nao Shibanuma, Toshihiro Akisue, Kotaro Nishida, Masahiro Kurosaka, Ryosuke Kuroda.   

Abstract

Although 2-dimensional assessments using postoperative plain radiographs have been used after total knee arthroplasty (TKA) in previous studies, a strong possibility exists that deviation can occur when assessing 3-dimensional (3-D) objects. The purpose of this study was to test the hypothesis that novel 3-D image-matching software could accurately assess the positioning of implants and could be a useful tool in postoperative evaluation after TKA.Total knee arthroplasty was performed in 30 consecutive patients. Intraoperatively, the thickness of each bone cut was measured. Postoperatively, the thickness of each part of the bone cut was measured using Athena Knee (SoftCube Co, Ltd, Osaka, Japan) 3-D image-matching software. The results revealed no significant differences in the medial compartment and significant differences of approximately 1 mm in the lateral compartment. The difference was possibly caused by the remaining cartilage in the lateral compartment. Linear regression analysis revealed a statistically excellent correlation between intra- and postoperative values in all parts of the bone cuts. Although the 3-D image-matching software used in this study was originally developed for preoperative planning in TKA, it is considered accurate enough to assess the positioning of implants with respect to the bone after TKA. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 23218626     DOI: 10.3928/01477447-20121120-14

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  11 in total

1.  Evaluation of patellofemoral joint in ADVANCE Medial-pivot total knee arthroplasty.

Authors:  Nobuaki Chinzei; Kazunari Ishida; Tomoyuki Matsumoto; Yuichi Kuroda; Atsushi Kitagawa; Ryosuke Kuroda; Toshihiro Akisue; Kotaro Nishida; Masahiro Kurosaka; Nobuhiro Tsumura
Journal:  Int Orthop       Date:  2013-08-08       Impact factor: 3.075

2.  Navigation-based femorotibial rotation pattern correlated with flexion angle after total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Hiroshi Sasaki; Koji Takayama; Tokio Matsuzaki; Katsumasa Tei; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-27       Impact factor: 4.342

3.  Mechanically aligned total knee arthroplasty carries a risk of bony gap changes and flexion-extension axis displacement.

Authors:  Yasuo Niki; Tomoki Sassa; Katsuya Nagai; Kengo Harato; Shu Kobayashi; Taro Yamashita
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-02-21       Impact factor: 4.342

4.  Effects of femoral bone tunnel characteristics on graft-bending angle in double-bundle anterior cruciate ligament reconstruction: a comparison of the outside-in and transportal techniques.

Authors:  Yasuo Niki; Katsuya Nagai; Kengo Harato; Yasunori Suda; Masaya Nakamura; Morio Matsumoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-08-21       Impact factor: 4.342

5.  Comparison between cylindrical axis-reference and articular surface-reference femoral bone cut for total knee arthroplasty.

Authors:  Yasuo Niki; Katsuya Nagai; Tomoki Sassa; Kengo Harato; Yasunori Suda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-02       Impact factor: 4.342

6.  Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Hiroshi Sasaki; Koji Takayama; Akihiko Toda; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-03-13       Impact factor: 4.342

7.  Tibiofemoral rotational alignment affects flexion angles in navigated posterior-stabilized total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Akihiko Toda; Shinya Oka; Kazuki Kodato; Koji Takayama; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

8.  Evaluation of the rotational alignment of the tibial component in total knee arthroplasty: position prioritizing maximum coverage.

Authors:  Masashi Hirakawa; Masashi Miyazaki; Shinichi Ikeda; Yoshiki Matsumoto; Makoto Kondo; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-09-10

9.  Navigation-based tibial rotation at 90° of flexion is associated with better range of motion in navigated total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Hiroshi Sasaki; Koji Takayama; Yuji Hiroshima; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-04       Impact factor: 4.342

10.  Fibular axes are not a reliable landmark for tibial mechanical axes of osteoarthritic knees that underwent total knee arthroplasty.

Authors:  Yuichi Kuroda; Kazunari Ishida; Tomoyuki Matsumoto; Hiroshi Sasaki; Tokio Matsuzaki; Shinya Oka; Koji Takayama; Katsumasa Tei; Takehiko Matsushita; Nobuhiro Tsumura; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-31       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.