Success rate of BladderScan-assisted suprapubic aspiration.

Davina Buntsma1, Amanda Stock, Catherine Bevan, Franz E Babl.   

Abstract

OBJECTIVE: Suprapubic aspiration (SPA) is the gold standard for obtaining uncontaminated urine specimens in young febrile children. The use of real-time ultrasound (RTUS) has been shown to increase the success rate of SPA. The BladderScan (BSUS) Verathon(®) is an alternative portable ultrasound device designed to provide automated measurement of bladder volume. Although simple and requiring minimal training, there are no data on the success rate of SPA using the device.
METHODS: An audit of current SPA practice using BSUS in the ED of a tertiary referral children's hospital was conducted. We assessed the success rate of SPA to obtain urine and correlate with BSUS readings and techniques.
RESULTS: Sixty SPAs (mean age 5.0 months) were observed over an 8-month period between August 2009 and March 2010. The audit showed an overall success rate of 53% (32/60) [95% confidence interval 41-66%]. Success rates were 63%, 32%, 82% and 63% for the largest BSUS readings of 0-9 mL (n = 8), 10-19 mL (n = 25), 20-29 mL (n = 11) and 30+ mL (n = 16), respectively, or 39% at <20 mL and 70% at ≥20 mL (P = 0.02).
CONCLUSION: The success rate of SPA in 'real-life' non-standardised clinical practice was low at 53% overall. The BSUS-assisted SPA success rate was higher in patients with readings ≥20 mL. These rates are lower than success rates reported using RTUS. Parameters for using BSUS to assist SPA should be established.
© 2012 The Authors. EMA © 2012 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

Entities:  

Mesh:

Year:  2012        PMID: 23216726     DOI: 10.1111/1742-6723.12011

Source DB:  PubMed          Journal:  Emerg Med Australas        ISSN: 1742-6723            Impact factor:   2.151


  3 in total

Review 1.  Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Authors:  Jennifer R Marin; Alyssa M Abo; Alexander C Arroyo; Stephanie J Doniger; Jason W Fischer; Rachel Rempell; Brandi Gary; James F Holmes; David O Kessler; Samuel H F Lam; Marla C Levine; Jason A Levy; Alice Murray; Lorraine Ng; Vicki E Noble; Daniela Ramirez-Schrempp; David C Riley; Turandot Saul; Vaishali Shah; Adam B Sivitz; Ee Tein Tay; David Teng; Lindsey Chaudoin; James W Tsung; Rebecca L Vieira; Yaffa M Vitberg; Resa E Lewiss
Journal:  Crit Ultrasound J       Date:  2016-11-03

Review 2.  Point of care ultrasonography in the pediatric emergency department.

Authors:  Julien Le Coz; Silvia Orlandini; Luigi Titomanlio; Victoria Elisa Rinaldi
Journal:  Ital J Pediatr       Date:  2018-07-27       Impact factor: 2.638

Review 3.  Non-radiologist-performed abdominal point-of-care ultrasonography in paediatrics - a scoping review.

Authors:  Elsa A van Wassenaer; Joost G Daams; Marc A Benninga; Karen Rosendahl; Bart G P Koot; Samuel Stafrace; Owen J Arthurs; Rick R van Rijn
Journal:  Pediatr Radiol       Date:  2021-04-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.