Literature DB >> 23215481

88Sr+ 445-THz single-ion reference at the 10(-17) level via control and cancellation of systematic uncertainties and its measurement against the SI second.

Alan A Madej1, Pierre Dubé, Zichao Zhou, John E Bernard, Marina Gertsvolf.   

Abstract

We describe experiments and measurements on a trapped and laser-cooled single ion of (88)Sr(+) which, when probed on its reference 5s (2)S(1/2)→4d (2)D(5/2) transition at 445 THz, provides an optical frequency standard of evaluated accuracy outperforming the current realization of the SI second. Studies are presented showing that micromotion-associated shifts of the standard can be reduced to the 10(-18) level and uncertainties in the blackbody-induced shifts for the current system are at the low 10(-17) level due to the relatively well-known polarizability of the strontium ion system and careful choice of the trap structure. The current evaluated systematic shifts for the ion transition are at a fractional uncertainty of 2×10(-17). An absolute frequency measurement performed over a two-month period relative to a maser referenced to the SI second via Global Positioning System time transfer has determined the center frequency for the transition at ν(SD)=444 779 044 095 485.5±0.9  Hz (1σ).

Entities:  

Year:  2012        PMID: 23215481     DOI: 10.1103/PhysRevLett.109.203002

Source DB:  PubMed          Journal:  Phys Rev Lett        ISSN: 0031-9007            Impact factor:   9.161


  5 in total

1.  Michelson-Morley analogue for electrons using trapped ions to test Lorentz symmetry.

Authors:  T Pruttivarasin; M Ramm; S G Porsev; I I Tupitsyn; M S Safronova; M A Hohensee; H Häffner
Journal:  Nature       Date:  2015-01-29       Impact factor: 49.962

2.  Operation of an optical atomic clock with a Brillouin laser subsystem.

Authors:  William Loh; Jules Stuart; David Reens; Colin D Bruzewicz; Danielle Braje; John Chiaverini; Paul W Juodawlkis; Jeremy M Sage; Robert McConnell
Journal:  Nature       Date:  2020-12-09       Impact factor: 49.962

3.  An optical lattice clock with accuracy and stability at the 10(-18) level.

Authors:  B J Bloom; T L Nicholson; J R Williams; S L Campbell; M Bishof; X Zhang; W Zhang; S L Bromley; J Ye
Journal:  Nature       Date:  2014-01-22       Impact factor: 49.962

4.  Coherent laser spectroscopy of highly charged ions using quantum logic.

Authors:  P Micke; T Leopold; S A King; E Benkler; L J Spieß; L Schmöger; M Schwarz; J R Crespo López-Urrutia; P O Schmidt
Journal:  Nature       Date:  2020-01-29       Impact factor: 49.962

5.  Systematic evaluation of an atomic clock at 2 × 10(-18) total uncertainty.

Authors:  T L Nicholson; S L Campbell; R B Hutson; G E Marti; B J Bloom; R L McNally; W Zhang; M D Barrett; M S Safronova; G F Strouse; W L Tew; J Ye
Journal:  Nat Commun       Date:  2015-04-21       Impact factor: 14.919

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.