Literature DB >> 232141

Comparison of four-layer radioimmunoassay and electron microscopy for detection of human rotavirus.

H K Sarkkinen, P E Halonen, P P Arstila.   

Abstract

A four-layer radioimmunoassay (RIA) using polystyrene beads as the solid phase, anti-rota guinea pig IgG as primary antibody, anti-rota rabbit IgG as secondary antibody, and 125I-labelled sheep anti-rabbit immunoglobulin as indicator antibody has been developed for the detection of human rotavirus in stool specimens. A comparison was made of the developed RIA, routine electron microscopy, and research electron microscopy of 147 unconcentrated stool specimens from patients with infantile gastroenteritis. In routine electron microscopy 17 (11.6%) false-positive or false-negative results were obtained when compared with research electron microscopy. Each specimen positive in research electron microscopy was positive in RIA, and six additional RIA positives were found from 58 electron microscopy negative specimens. A confirmatory test was necessary to find out marginally positive but nonspecific reactions in RIA. The developed radioimmunoassay is slightly more sensitive than research electron microscopy of unconcentrated stool specimens and considerably more sensitive and more specific than routine electron microscopy.

Entities:  

Mesh:

Year:  1979        PMID: 232141     DOI: 10.1002/jmv.1890040403

Source DB:  PubMed          Journal:  J Med Virol        ISSN: 0146-6615            Impact factor:   2.327


  8 in total

1.  Latex immunoassay for rapid detection of rotavirus.

Authors:  J H Hughes; A V Tuomari; D R Mann; V V Hamparian
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

2.  Microtiter solid-phase radioimmunoassay for detection of human calicivirus in stools.

Authors:  S Nakata; S Chiba; H Terashima; Y Sakuma; R Kogasaka; T Nakao
Journal:  J Clin Microbiol       Date:  1983-02       Impact factor: 5.948

3.  Detection of poliovirus antigen by enzyme immunoassay.

Authors:  P Ukkonen; A Huovilainen; T Hovi
Journal:  J Clin Microbiol       Date:  1986-12       Impact factor: 5.948

4.  Detection of respiratory syncytial, parainfluenza type 2, and adenovirus antigens by radioimmunoassay and enzyme immunoassay on nasopharyngeal specimens from children with acute respiratory disease.

Authors:  H K Sarkkinen; P E Halonen; P P Arstila; A A Salmi
Journal:  J Clin Microbiol       Date:  1981-02       Impact factor: 5.948

5.  Four-layer radioimmunoassay for detection of adenovirus in stool.

Authors:  P Halonen; H Sarkkinen; P Arstila; E Hjertsson; E Torfason
Journal:  J Clin Microbiol       Date:  1980-06       Impact factor: 5.948

6.  Rotavirus, adenovirus, and non-viral enteropathogens in diarrhoea.

Authors:  T Vesikari; M Mäki; H K Sarkkinen; P P Arstila; P E Halonen
Journal:  Arch Dis Child       Date:  1981-04       Impact factor: 3.791

7.  Human rotavirus antigen detection by enzyme-immunoassay with antisera against Nebraska calf diarrhoea virus.

Authors:  H K Sarkkinen
Journal:  J Clin Pathol       Date:  1981-06       Impact factor: 3.411

Review 8.  Diagnostic virology using electron microscopic techniques.

Authors:  A M Field
Journal:  Adv Virus Res       Date:  1982       Impact factor: 9.937

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.