Literature DB >> 23213936

Accuracy and benefits of 3D bone surface modelling: a comparison of two methods of surface data acquisition reconstructed by laser scanning and computed tomography outputs.

Hana Brzobohatá1, Josef Prokop, Martin Horák, Alexandr Jancárek, Jana Velemínská.   

Abstract

The aim of this study is to compare two different methods of frontal bone surface model acquisition. Three dimensional models acquired by laser scanning were compared with models of the same bones acquired by virtual replicas reconstructed from a sequence of computed tomography (CT) images. The influence of volumetric CT data processing (namely thresholding), which immediately preceded the generation of the three-dimensional surface model, was also considered and explored in detail in one sample. Despite identifying certain areas where both models showed deviations across all samples, their conformity can be generally classified as satisfactory, and the differences can be regarded as minimal. The average deviation of registered surface models was 0.27 mm for 90% of the data, and its value was therefore very close to the resolution of the laser scanner used.

Mesh:

Year:  2012        PMID: 23213936

Source DB:  PubMed          Journal:  Coll Antropol        ISSN: 0350-6134


  4 in total

1.  Pair-Matching Digital 3D Models of Temporomandibular Fragments Using Mesh-To-Mesh Value Comparison and Implications for Commingled Human Remain Assemblages.

Authors:  Alana S Acuff; Mara A Karell; Konstantinos E Spanakis; Elena F Kranioti
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

2.  Sexual Dimorphism of the Human Tibia through Time: Insights into Shape Variation Using a Surface-Based Approach.

Authors:  Hana Brzobohatá; Václav Krajíček; Zdeněk Horák; Jana Velemínská
Journal:  PLoS One       Date:  2016-11-15       Impact factor: 3.240

3.  Exploring sexual dimorphism of the modern human talus through geometric morphometric methods.

Authors:  Rita Sorrentino; Maria Giovanna Belcastro; Carla Figus; Nicholas B Stephens; Kevin Turley; William Harcourt-Smith; Timothy M Ryan; Stefano Benazzi
Journal:  PLoS One       Date:  2020-02-14       Impact factor: 3.240

4.  Comparability of skeletal fibulae surfaces generated by different source scanning (dual-energy CT scan vs. high resolution laser scanning) and 3D geometric morphometric validation.

Authors:  Annalisa Pietrobelli; Rita Sorrentino; Veronica Notariale; Stefano Durante; Stefano Benazzi; Damiano Marchi; Maria Giovanna Belcastro
Journal:  J Anat       Date:  2022-06-25       Impact factor: 2.921

  4 in total