Literature DB >> 23212079

In vitro and in vivo evaluation of the bioactivity of hydroxyapatite-coated polyetheretherketone biocomposites created by cold spray technology.

Jae Hyup Lee1, Hae Lin Jang, Kyung Mee Lee, Hae-Ri Baek, Kyoungsuk Jin, Kug Sun Hong, Jun Hong Noh, Hyun-Kyung Lee.   

Abstract

Polyetheretherketone (PEEK) is a material that is widely used in medicine because its mechanical properties show excellent similarity to those of human bone. However, because it is bioinert, PEEK shows limited ability to bind to natural bone tissue. Here, we applied a cold spray method to make a hydroxyapatite (HA)-coated PEEK hybrid material and evaluated its osteointegration in vitro and in vivo. With the cold spray method, the HA coating formed a homogeneous layer and adhered strongly to the PEEK disk implant. When the material was tested in vitro, early cell adhesion and viability improved. Alkaline phosphatase (ALP) activity and calcium concentration were also higher in cells cultured on HA-coated PEEK disks. In addition, the expression of osteoblast differentiation markers, such as ALP, bone sialoprotein and runt-related transcription factor 2, increased in these cells. For the in vivo test, we designed and implanted HA-coated PEEK cylinders into a rabbit ilium model by the press-fit method. The bone-implant contact ratio, trabecular number and trabecular thickness were determined using either three-dimensional microcomputed tomography or general two-dimensional histomorphometric analysis. This report demonstrates that the HA coating on the PEEK implant added with the cold spray method increased biocompatibility in vitro and promoted osteointegration in vivo, which suggests that the HA coating may improve the biofunctionality of various medical devices used in clinical applications.
Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23212079     DOI: 10.1016/j.actbio.2012.11.030

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  27 in total

1.  In vivo evaluation of the bone integration of coated poly(vinyl-alcohol) hydrogel fiber implants.

Authors:  David Moreau; Arthur Villain; Manon Bachy; Henry Proudhon; David N Ku; Didier Hannouche; Hervé Petite; Laurent Corté
Journal:  J Mater Sci Mater Med       Date:  2017-06-19       Impact factor: 3.896

2.  Fabrication of a novel hydroxyapatite/polyether ether ketone surface nanocomposite via friction stir processing for orthopedic and dental applications.

Authors:  Davood Almasi; Woei Jye Lau; Sajad Rasaee; Roohollah Sharifi; Hamid Reza Mozaffari
Journal:  Prog Biomater       Date:  2020-05-03

3.  Rapid coating of surfaces with functionalized nanoparticles for regulation of cell behavior.

Authors:  Rui Tang; Daniel F Moyano; Chandramouleeswaran Subramani; Bo Yan; Eunhee Jeoung; Gülen Yesilbag Tonga; Bradley Duncan; Yi-Cheun Yeh; Ziwen Jiang; Chaekyu Kim; Vincent M Rotello
Journal:  Adv Mater       Date:  2014-02-21       Impact factor: 30.849

4.  Deposition, Heat Treatment And Characterization of Two Layer Bioactive Coatings on Cylindrical PEEK.

Authors:  John W Durham; Afsaneh Rabiei
Journal:  Surf Coat Technol       Date:  2015-12-17       Impact factor: 4.158

5.  Hydroxyapatite coating on PEEK implants: Biomechanical and histological study in a rabbit model.

Authors:  John W Durham; Sergio A Montelongo; Joo L Ong; Teja Guda; Matthew J Allen; Afsaneh Rabiei
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2016-06-15       Impact factor: 7.328

6.  Assessment of a polyelectrolyte multilayer film coating loaded with BMP-2 on titanium and PEEK implants in the rabbit femoral condyle.

Authors:  R Guillot; I Pignot-Paintrand; J Lavaud; A Decambron; E Bourgeois; V Josserand; D Logeart-Avramoglou; E Viguier; C Picart
Journal:  Acta Biomater       Date:  2016-03-07       Impact factor: 8.947

7.  Fabrication of Submicro-Nano Structures on Polyetheretherketone Surface by Femtosecond Laser for Exciting Cellular Responses of MC3T3-E1 Cells/Gingival Epithelial Cells.

Authors:  Dong Xie; Chenhui Xu; Cheng Ye; Shiqi Mei; Longqing Wang; Qi Zhu; Qing Chen; Qi Zhao; Zhiyan Xu; Jie Wei; Lili Yang
Journal:  Int J Nanomedicine       Date:  2021-05-10

8.  Optimizing the layer thickness of sol-gel-derived TiO2 coating on polyetheretherketone.

Authors:  Makoto Hayashi; Takayoshi Shimizu; Masashi Imamura; Shunsuke Fujibayashi; Seiji Yamaguchi; Koji Goto; Bungo Otsuki; Toshiyuki Kawai; Yaichiro Okuzu; Shuichi Matsuda
Journal:  Sci Rep       Date:  2021-08-05       Impact factor: 4.379

Review 9.  Current strategies to improve the bioactivity of PEEK.

Authors:  Rui Ma; Tingting Tang
Journal:  Int J Mol Sci       Date:  2014-03-28       Impact factor: 5.923

10.  Biomechanical evaluation and surface characterization of a nano-modified surface on PEEK implants: a study in the rabbit tibia.

Authors:  Pär Johansson; Ryo Jimbo; Per Kjellin; Fredrik Currie; Bruno Ramos Chrcanovic; Ann Wennerberg
Journal:  Int J Nanomedicine       Date:  2014-08-14
View more