Literature DB >> 23211549

Longitudinal NMR parameter measurements of Japanese pear fruit during the growing process using a mobile magnetic resonance imaging system.

Yuto Geya1, Takeshi Kimura, Hirotaka Fujisaki, Yasuhiko Terada, Katsumi Kose, Tomoyuki Haishi, Hiroshi Gemma, Yoshihiko Sekozawa.   

Abstract

Longitudinal nuclear magnetic resonance (NMR) parameter measurements of Japanese pear fruit (Pyrus pyrifolia Nakai, Kosui) were performed using an electrically mobile magnetic resonance imaging (MRI) system with a 0.2 T and 16 cm gap permanent magnet. To measure the relaxation times and apparent diffusion coefficients of the pear fruit in relation to their weight, seven pear fruits were harvested almost every week during the cell enlargement period and measured in a research orchard. To evaluate the in situ relaxation times, six pear fruits were longitudinally measured for about two months during the same period. The measurements for the harvested samples showed good agreement with the in situ measurements. From the measurements of the harvested samples, it is clear that the relaxation rates of the pear fruits linearly change with the inverse of the linear dimension of the fruits, demonstrating that the relaxation mechanism is a surface relaxation. We therefore conclude that the mobile MRI system is a useful device for measuring the NMR parameters of outdoor living plants.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23211549     DOI: 10.1016/j.jmr.2012.10.012

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  4 in total

1.  Incidence of elbow injuries in adolescent baseball players: screening by a low field magnetic resonance imaging system specialized for small joints.

Authors:  Yoshikazu Okamoto; Kiyoshi Maehara; Tetsuya Kanahori; Takashi Hiyama; Takashi Kawamura; Manabu Minami
Journal:  Jpn J Radiol       Date:  2016-02-08       Impact factor: 2.374

2.  Characterization of the Water Shortage Effects on Potato Tuber Tissues during Growth Using MRI Relaxometry and Biochemical Parameters.

Authors:  Ghina Hajjar; Stéphane Quellec; Sylvain Challois; Lydia Bousset-Vaslin; Gisèle Joly; Christophe Langrume; Carole Deleu; Laurent Leport; Maja Musse
Journal:  Plants (Basel)       Date:  2022-07-25

3.  A mobile NMR lab for leaf phenotyping in the field.

Authors:  Maja Musse; Laurent Leport; Mireille Cambert; William Debrandt; Clément Sorin; Alain Bouchereau; François Mariette
Journal:  Plant Methods       Date:  2017-06-28       Impact factor: 4.993

Review 4.  Sensors and Instruments for Brix Measurement: A Review.

Authors:  Swapna A Jaywant; Harshpreet Singh; Khalid Mahmood Arif
Journal:  Sensors (Basel)       Date:  2022-03-16       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.