| Literature DB >> 23206398 |
Ji-Ye Lee1, Young Ah Kim, Mi Yeon Kim, Yong Tae Lee, Bruce D Hammock, Hye-Sung Lee.
Abstract
This study was performed to demonstrate the importance of selecting an appropriate membrane when developing immunochromatographic assays (ICAs) for the sensitive detection of low-molecular weight compounds. Based on our findings, we propose a theoretical basis for selecting such a membrane. When eluting the sample solution for the competitive ICA using colloidal gold label for low-molecular analytes, the degree of binding inhibition is proportional to the collision frequency between the antibody-colloidal gold (Ab-CG) and analyte before Ab-CG binding to the capture antigen and a higher concentration of pesticides around the Ab-CG leads to a greater degree of inhibition. Therefore, we propose that the relative migration speed of the analyte and Ab-CG on the test strip is critically important for selecting a membrane in the development of sensitive competitive ICAs. We developed a novel method to estimate such a relative migration speed. We demonstrated the applicability of this proposal by using it to select an appropriate membrane for the development of an ICA of the pesticide diazinon.Entities:
Mesh:
Substances:
Year: 2012 PMID: 23206398 PMCID: PMC4113188 DOI: 10.1016/j.aca.2012.10.052
Source DB: PubMed Journal: Anal Chim Acta ISSN: 0003-2670 Impact factor: 6.558