Literature DB >> 23205173

Use of orthodontic mini-implants for maxillomandibular fixation in mandibular fracture.

Mario Sergio Medeiros Pires1, Leandro Calcagno Reinhardt, Guilherme de Marco Antonello, Ricardo Torres do Couto.   

Abstract

Orthodontic appliances for skeletal anchorage are becoming increasingly more common in clinical practice. Similarly, different terms such as mini-implants, microimplants, and miniscrews have been used. There is a wide array of appliances currently on the market, in different designs and sizes, diameters, degree of titanium purity, and surface treatment. These appliances have been used for a variety of indications, including tooth retraction, intrusion, and traction. This study aimed to report the clinical case of a 19-year-old patient with a fractured mandible and to propose a novel use of mini-implants: the perioperative placement of mini-implants as anchors for maxillomandibular fixation steel wire ligatures. We concluded that this appliance provides an effective maxillomandibular fixation in patients with mandibular fracture, with little increase in the cost of surgery.

Entities:  

Keywords:  Mini-implants; mandibular fracture; maxillomandibular fixation

Year:  2011        PMID: 23205173      PMCID: PMC3314252          DOI: 10.1055/s-0031-1293522

Source DB:  PubMed          Journal:  Craniomaxillofac Trauma Reconstr        ISSN: 1943-3875


  21 in total

1.  The spider screw for skeletal anchorage.

Authors:  B Giuliano Maino; John Bednar; Paolo Pagin; Paola Mura
Journal:  J Clin Orthod       Date:  2003-02

2.  Development of orthodontic micro-implants for intraoral anchorage.

Authors:  Hee-Moon Kyung; Hyo-Sang Park; Seong-Min Bae; Jae-Hyun Sung; Il-Bong Kim
Journal:  J Clin Orthod       Date:  2003-06

3.  Uprighting second molars with micro-implant anchorage.

Authors:  Hyo-Sang Park; Oh-Won Kwon; Jae-Hyun Sung
Journal:  J Clin Orthod       Date:  2004-02

4.  Miniscrew anchorage used to protract lower second molars into first molar extraction sites.

Authors:  Seung-Hyun Kyung; Ju-Hee Choi; Young-Chel Park
Journal:  J Clin Orthod       Date:  2003-10

5.  A radiographic evaluation of the availability of bone for placement of miniscrews.

Authors:  Marissa A Schnelle; Frank Michael Beck; Robert M Jaynes; Sarandeep S Huja
Journal:  Angle Orthod       Date:  2004-12       Impact factor: 2.079

6.  The use of microimplants in orthodontic anchorage.

Authors:  Chung-Ho Chen; Chao-San Chang; Chi-Hsin Hsieh; Yu-Chuan Tseng; Yee-Shyong Shen; I-Yueh Huang; Chia-Fu Yang; Chun-Ming Chen
Journal:  J Oral Maxillofac Surg       Date:  2006-08       Impact factor: 1.895

Review 7.  Correction of skeletal open bite with implant anchored molar/bicuspid intrusion.

Authors:  Keith Sherwood
Journal:  Oral Maxillofac Surg Clin North Am       Date:  2007-08       Impact factor: 2.802

8.  Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study.

Authors:  Dirk Wiechmann; Ulrich Meyer; André Büchter
Journal:  Clin Oral Implants Res       Date:  2007-04       Impact factor: 5.977

9.  Simple technique for maxillomandibular fixation using patient's denture and anchorage screws.

Authors:  Yong-Wook Jang; Seong-Gon Kim
Journal:  J Oral Maxillofac Surg       Date:  2009-01       Impact factor: 1.895

10.  Mandibular osteosynthesis by miniature screwed plates via a buccal approach.

Authors:  M Champy; J P Loddé; R Schmitt; J H Jaeger; D Muster
Journal:  J Maxillofac Surg       Date:  1978-02
View more
  1 in total

1.  Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs).

Authors:  Andrea Scribante; Mona A Montasser; Eman Saad Radwan; Luisa Bernardinelli; Roberto Alcozer; Paola Gandini; Maria Francesca Sfondrini
Journal:  Materials (Basel)       Date:  2018-07-05       Impact factor: 3.623

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.