Literature DB >> 23203780

Effect of test duration on the visual-evoked potential (VEP) and alpha-wave responses.

Kevin T Willeford1, Kenneth J Ciuffreda, Naveen K Yadav.   

Abstract

PRIMARY
OBJECTIVE: The purpose of this study was to assess the effect of test duration on the visual-evoked potential (VEP) and related alpha power spectrum measures. DESIGN AND METHODS: Two conditions (eyes-closed and eyes-open) were tested using four different durations: 10, 20, 45, and 60 s. The Diopsys™ NOVA-TR system was used to obtain the visual-evoked potential (VEP) and extracted alpha wave with its related power spectrum. Sixteen visually normal, young-adult subjects (aged 22-25 years) participated in the experiment. The stimulus for the eyes-open condition consisted of a black-and-white, alternating checkerboard pattern with a small central fixation target. All trials were performed during one session.
RESULTS: Regarding the VEP parameters, only variability of the VEP amplitude changed significantly with test duration. Sentence should end with a period, not a colon. It decreased with increasing test duration, with the 45- and 60-s trials showing similarly low variability. Regarding the alpha-wave parameters, test duration did not have a significant effect on either the mean alpha power or its variability across trials.
CONCLUSIONS: The findings demonstrate that forty-five-second test durations are sufficient to minimize intra-session variability of the VEP amplitude and latency measurements, whereas 10-s test durations may be sufficient for accurate measurement of the alpha wave. Optimization of test duration allows for repeatable measures with less total test time. This is especially important for special clinical populations.

Entities:  

Mesh:

Year:  2012        PMID: 23203780      PMCID: PMC4096719          DOI: 10.1007/s10633-012-9363-9

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  38 in total

1.  Low response variability in simultaneously recorded retinal, thalamic, and cortical neurons.

Authors:  P Kara; P Reinagel; R C Reid
Journal:  Neuron       Date:  2000-09       Impact factor: 17.173

2.  Cortical sources of the early components of the visual evoked potential.

Authors:  Francesco Di Russo; Antígona Martínez; Martin I Sereno; Sabrina Pitzalis; Steven A Hillyard
Journal:  Hum Brain Mapp       Date:  2002-02       Impact factor: 5.038

3.  Test-retest reliability of spectral parameters of the EEG.

Authors:  T Gasser; P Bächer; H Steinberg
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1985-04

4.  Inter-session stability of human alpha rhythm densities.

Authors:  J J Lynch; D A Paskewitz; M T Orne
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1974-05

Review 5.  Spectral analysis of the EEG. Some fundamentals revisited and some open problems.

Authors:  G Dumermuth; L Molinari
Journal:  Neuropsychobiology       Date:  1987       Impact factor: 2.328

6.  Individual differences in the human electroencephalogram during quiet wakefulness.

Authors:  H van Dis; M Corner; R Dapper; G Hanewald; H Kok
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1979-07

7.  How to select epochs of the EEG at rest for quantitative analysis.

Authors:  J Möcks; T Gasser
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1984-07

8.  Attention and the EEG alpha rhythm in learning disabled children.

Authors:  P W Fuller
Journal:  J Learn Disabil       Date:  1978-05

9.  The statistical reliability of signals in single neurons in cat and monkey visual cortex.

Authors:  D J Tolhurst; J A Movshon; A F Dean
Journal:  Vision Res       Date:  1983       Impact factor: 1.886

10.  Objective assessment of the human visual attentional state.

Authors:  Kevin T Willeford; Kenneth J Ciuffreda; Naveen K Yadav; Diana P Ludlam
Journal:  Doc Ophthalmol       Date:  2012-10-31       Impact factor: 2.379

View more
  2 in total

1.  Visual evoked potential repeatability using the Diopsys NOVA LX fixed protocol in normal older adults.

Authors:  Richard C Trevino; Carolyn E Majcher; Adreain M Henry; Melinda Rodriguez; William E Sponsel
Journal:  Clin Ophthalmol       Date:  2018-09-07

2.  Effect of chromatic filters on visual performance in individuals with mild traumatic brain injury (mTBI): A pilot study.

Authors:  Vanessa Fimreite; Kevin T Willeford; Kenneth J Ciuffreda
Journal:  J Optom       Date:  2016-05-30