Literature DB >> 23201624

Evaluation of lower limb electromyographic activity when using unstable shoes for the first time: a pilot quasi control trial.

Helen Branthwaite1, Nachiappan Chockalingam, Anand Pandyan, Gaurav Khatri.   

Abstract

BACKGROUND: Unstable shoes, which have recently become popular, claim to provide additional physiological and biomechanical advantages to people who wear them. Alterations in postural stability have been shown when using the shoe after training. However, the immediate effect on muscle activity when walking in unstable shoes for the first time has not been investigated.
OBJECTIVE: To evaluate muscle activity and temporal parameters of gait when wearing Masai Barefoot Technology shoes(®) for the first time compared to the subject's own regular trainer shoes. STUDY
DESIGN: A pilot repeated-measures quasi control trial.
METHOD: Electromyographic measurements of lower leg muscles (soleus, medial gastrocnemius, lateral gastrocnemius, tibialis anterior, peroneus longus, rectus femoris, biceps femoris and gluteus medius) were measured in 15 healthy participants using Masai Barefoot Technology shoes and trainer shoes over a 10-m walkway. Muscle activity of the third and sixth steps was used to study the difference in behaviour of the muscles under the two shoe conditions. Temporal parameters were captured with footswitches to highlight heel strike, heel lift and toe off. Paired samples t-test was completed to compare mean muscle activity for Masai Barefoot Technology and trainer shoes.
RESULTS: Indicated that the use of Masai Barefoot Technology shoes increased the intensity of the magnitude of muscle activity. While this increase in the activity was not significant across the subjects, there were inter-individual differences in muscle activity. This variance between the participants demonstrates that some subjects do alter muscle behaviour while wearing such shoes.
CONCLUSION: A more rigorous and specific assessment is required when advising patients to purchase the Masai Barefoot Technology shoe. Not all subjects respond positively to using unstable shoes, and the point in time when muscle behaviour can change is variable. CLINICAL RELEVANCE: Use of Masai Barefoot Technology shoe in patient management should be monitored closely as the individual muscle changes and the point in time when changes occur vary between subjects, and evaluation of how a subject responds is not yet clear.

Entities:  

Keywords:  Masai Barefoot Technology shoes; electromyography; muscle activity

Mesh:

Year:  2012        PMID: 23201624     DOI: 10.1177/0309364612464812

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  4 in total

Review 1.  Biomechanical and neural changes evaluation induced by prolonged use of non-stable footwear: a systematic review.

Authors:  R Papalia; G Di Pino; A Tecame; G Vadalà; D Formica; A Di Martino; E Albo; V Di Lazzaro; V Denaro
Journal:  Musculoskelet Surg       Date:  2015-04-11

2.  The effect of shoe toe box shape and volume on forefoot interdigital and plantar pressures in healthy females.

Authors:  Helen Branthwaite; Nachiappan Chockalingam; Andrew Greenhalgh
Journal:  J Foot Ankle Res       Date:  2013-07-25       Impact factor: 2.303

3.  Post-marathon wearing of Masai Barefoot Technology shoes facilitates recovery from race-induced fatigue: an evaluation utilizing a visual analog scale.

Authors:  Kento Nakagawa; Takashi Obu; Kazuyuki Kanosue
Journal:  Open Access J Sports Med       Date:  2014-12-08

4.  Medical-grade footwear: the impact of fit and comfort.

Authors:  Bessie Hurst; Helen Branthwaite; Andrew Greenhalgh; Nachiappan Chockalingam
Journal:  J Foot Ankle Res       Date:  2017-01-05       Impact factor: 2.303

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.