Literature DB >> 23200425

Precision of maxillary repositioning during orthognathic surgery: a prospective study.

Carl Bouchard1, Pierre-Éric Landry.   

Abstract

The purpose of this study was to evaluate the accuracy of surgical splints and an external reference point to reposition the maxilla during orthognathic surgery. Before surgery, a radiological marker was inserted inside the orthodontic bracket of the first right maxillary molar. A surgical splint was utilized to reposition the maxilla in the sagittal and coronal planes after the osteotomy. The vertical position was established by measuring the distance between a Kirschner wire inserted at bony nasion and the orthodontic wire. Preoperative and postoperative cephalometric radiographs were obtained and manually traced. The radiological marker and the tip of the right maxillary incisor were used as specific landmarks. Their displacement on the pre- and postoperative radiographs was measured. The actual surgical movement of the maxilla was compared to the initial surgical planning. 23 patients met the inclusion criteria to participate in the study. The mean difference between the planned and executed movements of the maxilla was 0.1mm (p=0.71). The difference was not statistically significant for any given movements of the maxilla. The use of surgical splints made from model surgery combined with an external reference point at bony nasion is accurate methods for repositioning the maxilla during orthognathic surgery.
Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23200425     DOI: 10.1016/j.ijom.2012.10.034

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  3 in total

1.  Accuracy evaluation of CAD/CAM generated splints in orthognathic surgery: a cadaveric study.

Authors:  Thomas Schouman; Philippe Rouch; Benoît Imholz; Jean Fasel; Delphine Courvoisier; Paolo Scolozzi
Journal:  Head Face Med       Date:  2015-07-25       Impact factor: 2.151

2.  A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser.

Authors:  Frank Baan; Jeroen Liebregts; Tong Xi; Ruud Schreurs; Martien de Koning; Stefaan Bergé; Thomas Maal
Journal:  PLoS One       Date:  2016-02-22       Impact factor: 3.240

3.  What is the accuracy of the surgical guide in the planning of orthognathic surgeries? A systematic review.

Authors:  M-E Goulart; T-C Biegelmeyer; L Moreira-Souza; C-R Adami; F Deon; I-L Flores; T-O Gamba
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2022-03-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.