Literature DB >> 23200395

New potentiometric sensors based on selective recognition sites for determination of ephedrine in some pharmaceuticals and biological fluids.

Saad S M Hassan1, Ayman H Kamel, Heba Abd El-Naby.   

Abstract

New cost-effective potentiometric membrane sensors with cylindrical configuration responsive to ephedrine are described. The sensors setup is, based on the use of triacetyl-β-cyclodextrin [(triacetyl-β-CD)] as a neutral ionophore embedded in a plasticized poly (vinyl chloride) (PVC) matrix (sensor I) and carboxylated poly(vinyl chloride) [(PVC-COOH)] as a simultaneous plastic matrix and ion exchanger (sensor II). Both sensors showed significant enhancement of response towards ephedrinium cation (EPD(+)) over a concentration range of 3.0 × 10(-5)-8.0 × 10(-3) mol L(-1) at pH 4-9 and 3-8 with low detection limits of 5.7 × 10(-6) and 6.2 × 10(-6) mol L(-1) for sensors (I) and (II), respectively. The sensors displayed near-Nernstian cationic slope of 57.0 and 55.6 mV decade(-1) for EPD(+) and the effects of lipophilic salts and various foreign common ions were examined. The sensors were also satisfactorily used as tubular detectors in a double channel flow injection system. The intrinsic characteristics of the detectors in a low dispersion manifold under hydrodynamic mode of operation were determined and compared with data obtained under batch mode of operation. Validation of the method revealed good performance characteristics including long life span, good selectivity for EPD(+) over a wide variety of other organic compounds, long term stability, high reproducibility, fast response, low detection limit, wide measurement range, acceptable accuracy and precision. Applications of the sensors to the determination of EPD(+) in pharmaceutical formulations and spiked biological fluid samples were carried out and compared with standard techniques. Notably, the sensors introduced offer several advantages over many of those previously described that are amenable to quality control/quality assurance assessment of the homogeneity, stability and purity of ephedrine drug tablets.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23200395     DOI: 10.1016/j.talanta.2012.10.067

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Determination of pholcodine alone or in combination with ephedrine in human plasma using fluorescence spectroscopy.

Authors:  Heba Elmansi; Fathalla Belal; Galal Magdy
Journal:  Sci Rep       Date:  2022-06-07       Impact factor: 4.996

2.  Potentiometric determination of moxifloxacin in some pharmaceutical formulation using PVC membrane sensors.

Authors:  Mohammed M Hefnawy; Atef M Homoda; Mohammed A Abounassif; Amer M Alanazi; Abdulrahaman Al-Majed; Gamal A Mostafa
Journal:  Chem Cent J       Date:  2014-09-17       Impact factor: 4.215

3.  Calixarene based portable sensor for the direct assay of indiscriminate ephedrine content of weight loss herbal preparations.

Authors:  Mary E Wahba; Dalia El Wasseef; Ahmed S Saad; Mohammed E Draz
Journal:  RSC Adv       Date:  2021-04-06       Impact factor: 3.361

4.  Comparative study of β-cyclodextrin, γ-cyclodextrin and 4-tert-butylcalix[8]arene ionophores as electroactive materials for the construction of new sensors for trazodone based on host-guest recognition.

Authors:  Haitham Alrabiah; Haya I Aljohar; Ahmed Hassan Bakheit; Atef Ma Homoda; Gamal Abdel-Hafiz Mostafa
Journal:  Drug Des Devel Ther       Date:  2019-07-11       Impact factor: 4.162