Literature DB >> 23200021

In vivo assessment of liver fibrosis using diffuse reflectance and fluorescence spectroscopy: a proof of concept.

Diego Fabila1, José Manuel de la Rosa, Suren Stolik, Edgard Moreno, Karina Suárez-Álvarez, Giuliana López-Navarrete, Carolina Guzmán, Jesús Aguirre-García, Christian Acevedo-García, David Kershenobich, Galileo Escobedo.   

Abstract

A novel application of diffuse reflectance and fluorescence spectroscopy in the assessment of liver fibrosis is here reported. To induce different stages of liver fibrosis, a sufficient number of male Wistar rats were differentially exposed to chronic administration with carbon tetrachloride. Then, diffuse reflectance and fluorescence spectra were in vivo measured from the liver surface of each animal by a minimal invasive laparoscopic procedure. The liver fibrosis degree was conventionally determined by means of histological examination using the Mason's Trichrome stain, accompanied by hepatic expression of α-sma, and evaluation of the ALT/AST serum levels. The liver from rats exhibiting higher grades of fibrosis showed a significant increase in diffuse reflectance and fluorescence intensity when compared with control animals. At 365 nm, the diffuse reflectance spectrum exhibited an increase of 4 and 3-fold in mild and advanced fibrotic rats, respectively, when compared to the control group. Similarly, the fluorescence emission at 493 nm was 2-fold higher in fibrotic animals than in controls. By using fluorescence intensity, discrimination algorithms indicated 73% sensitivity and 94% specificity for recognition of hepatic fibrosis, while for diffuse reflectance, these values increased up to 85% and 100%, respectively. Taking into consideration there is a special need for developing new diagnostic approaches focused on detecting different stages of liver fibrosis with minimal invasiveness, these results suggest that diffuse reflectance and fluorescence spectroscopy could be worthy of further exploration in patients with liver disease.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23200021     DOI: 10.1016/j.pdpdt.2012.05.002

Source DB:  PubMed          Journal:  Photodiagnosis Photodyn Ther        ISSN: 1572-1000            Impact factor:   3.631


  4 in total

1.  Real-time calibrating polarization-sensitive diffuse reflectance handheld probe characterizes clinically relevant anatomical locations of oral tissue in vivo.

Authors:  Jianfeng Wang
Journal:  Biomed Opt Express       Date:  2021-12-06       Impact factor: 3.732

2.  Noninvasive evaluation of hemodynamics and light scattering property during two-stage mouse cutaneous carcinogenesis based on multispectral diffuse reflectance images at isosbestic wavelengths of hemoglobin.

Authors:  Md Abdul Wares; Naoki Tobita; Satoko Kawauchi; Shunichi Sato; Izumi Nishidate
Journal:  J Biomed Opt       Date:  2019-01       Impact factor: 3.170

3.  Automated morphometry provides accurate and reproducible virtual staging of liver fibrosis in chronic hepatitis C.

Authors:  Paul Calès; Julien Chaigneau; Gilles Hunault; Sophie Michalak; Christine Cavaro-Menard; Jean-Baptiste Fasquel; Sandrine Bertrais; Marie-Christine Rousselet
Journal:  J Pathol Inform       Date:  2015-05-28

4.  Fluorescence spectroscopy as an efficient tool for staging the degree of liver fibrosis: an in vivo comparison with MRI.

Authors:  Shaiju S Nazeer; Ariya Saraswathy; Sachin J Shenoy; Ramapurath S Jayasree
Journal:  Sci Rep       Date:  2018-07-20       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.