Indirect measurement of the vascular endothelial glycocalyx layer thickness in human submucosal capillaries with a plug-in for ImageJ.

Sasu Liuhanen1, Marko Sallisalmi, Ville Pettilä, Niku Oksala, Jyrki Tenhunen.   

Abstract

BACKGROUND: The thickness of vascular endothelial glycocalyx layer can be measured indirectly during a spontaneous leukocyte passage from oral submucosal capillaries in humans. The subsequent differences in red blood cell (RBC) column widths, before a spontaneous white blood cell passage (pre-WBC) and after a spontaneous WBC passage (post-WBC) can be used in off-line analysis to measure glycocalyx thickness: [pre-WBC width-post-WBC width]/2. We created and validated a semi-automatic plug-in for ImageJ to measure the endothelial glycocalyx layer thickness.
METHODS: Video clips presenting human sublingual microvasculature were created with a side-stream dark field imaging device. Spontaneous leukocyte passages in capillaries were analyzed from video clips with ImageJ. The capillary glycocalyx layer thickness was measured by the indirect approach with two manual and two semi-automatic methods.
RESULTS: There were no statistically significant differences between glycocalyx layer thicknesses measured with different methods, even though small inter-method differences in RBC column thicknesses could be detected. Inter-rater differences were systematically smaller with both semi-automatic methods. Intra-rater coefficient of variation [CV] (95% CI) was largest when measurements were made completely manually [9.2% (8.4-10.0)], but improved significantly with automatic image enhancement prior to manual measurement [7.2% (6.4-8.0)]. CV could be improved further when using semi-automatic analysis with an in-frame median filter radius of 1 pixel [5.8% (5.0-6.6)], or a median filter radius of 2 pixels [4.3% (3.5-5.1)].
CONCLUSIONS: Semi-automatic analysis of glycocalyx decreased the intra-rater CV and the inter-rater differences compared to the manual method. On average, each of the four methods yielded equal results for the glycocalyx thickness. Being the only feasible bed side method in most clinical scenarios, indirect measurement of glycocalyx thickness with orthogonal polarization spectral imaging or side-stream dark field imaging device and our plug-in can advance the study of glycocalyx layer pathology in man.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23195494     DOI: 10.1016/j.cmpb.2012.10.019

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  3 in total

Review 1.  Implications of recent accumulating knowledge about endothelial glycocalyx on anesthetic management.

Authors:  Ghada M N Bashandy
Journal:  J Anesth       Date:  2014-08-01       Impact factor: 2.078

2.  Automated Measurement of Microvascular Function Reveals Dysfunction in Systemic Sclerosis: A Cross-sectional Study.

Authors:  Daniel R Machin; Phillip E Gates; Hans Vink; Tracy M Frech; Anthony J Donato
Journal:  J Rheumatol       Date:  2017-09-15       Impact factor: 4.666

3.  Advanced age results in a diminished endothelial glycocalyx.

Authors:  Daniel R Machin; Samuel I Bloom; Robert A Campbell; Tam T T Phuong; Phillip E Gates; Lisa A Lesniewski; Matthew T Rondina; Anthony J Donato
Journal:  Am J Physiol Heart Circ Physiol       Date:  2018-05-11       Impact factor: 4.733

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.