Literature DB >> 23192204

Non-contrast-enhanced magnetic resonance angiography using T2-weighted 3-dimensional fat-suppressed turbo spin echo (SPACE): diagnostic performance and comparison with contrast-enhanced magnetic resonance angiography using volume interpolated breath-hold examination in the detection of portosystemic and portohepatic collaterals.

Qiong Song1, Mengsu Zeng, Caizhong Chen, Jing Ma, Hong Yun, Shengxiang Rao, Xiuzhong Yao.   

Abstract

OBJECTIVES: The objective of this study was to evaluate the diagnostic performance of non-contrast-enhanced magnetic resonance angiography (non-CE-MRA) using SPACE ("Sampling Perfection with Application optimized Contrasts using different flip angle Evolutions") in comparison with CE-MRA using volume interpolated breath-hold examination (VIBE) in the detection of portosystemic and portohepatic collaterals.
METHODS: Thirty consecutively enrolled cirrhotic patients with suspicion of portosystemic and portohepatic collaterals underwent SPACE followed by VIBE at 1.5-T magnetic resonance imaging scanner. The contrast-to-noise ratio, signal-to-noise ratio, and scores of the portal vein segments and overall image were used to compare the diagnostic performance of SPACE with that of VIBE. The paired Student t test and the Wilcoxon signed rank test were used for statistical analysis.
RESULTS: Diagnostic results of SPACE were equivalent to those of VIBE. However, both the signal-to-noise ratio and contrast-to-noise ratio of portal vein segments in the former were better than those in the latter (P < 0.0001), and the scores of displaying the portal vein distal branches in SPACE were higher than those in VIBE (P < 0.05).
CONCLUSIONS: The SPACE has a comparable ability in demonstrating portosystemic and portohepatic collaterals as well as VIBE does.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23192204     DOI: 10.1097/RCT.0b013e31826999df

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  2 in total

1.  Assessment of thoracic vasculature in patients with central bronchogenic carcinoma by unenhanced magnetic resonance angiography: comparison between 2D free-breathing TrueFISP, 2D breath-hold TrueFISP and 3D respiratory-triggered SPACE.

Authors:  Lili Wang; Peng Lv; Shuohui Yang; Mengsu Zeng; Jiang Lin
Journal:  J Thorac Dis       Date:  2017-06       Impact factor: 2.895

2.  Evaluation of aqueductal patency in patients with hydrocephalus: three-dimensional high-sampling-efficiency technique (SPACE) versus two-dimensional turbo spin echo at 3 Tesla.

Authors:  Murat Ucar; Melike Guryildirim; Nil Tokgoz; Koray Kilic; Alp Borcek; Yusuf Oner; Koray Akkan; Turgut Tali
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.