Literature DB >> 23192160

Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

Monvadi B Srichai1, Ruth P Lim, Narayan Lath, James Babb, Leon Axel, Daniel Kim.   

Abstract

OBJECTIVES: We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury.
BACKGROUND: Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse.
MATERIALS AND METHODS: A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (<30 days) troponin elevation greater than 2 times the upper limit of normal as the reference standard for acute myocardial injury.
RESULTS: Of the 65 patients, there were 21 (32%) with acute myocardial injury. Image quality and artifact scores were significantly better with FSE-SPAIR compared with FSE-STIR (2.15 vs 2.68, P < 0.01; 2.62 vs 3.05, P < 0.01, respectively). The sensitivity, specificity, positive predictive value, and negative predictive value for acute myocardial injury were as follows: 29%, 93%, 67%, and 73% for FSE-SPAIR; 38%, 91%, 67%, and 75% for FSE-STIR; 71%, 98%, 94%, and 88% for clinical interpretation including LGE, T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence.
CONCLUSIONS: Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23192160     DOI: 10.1097/RLI.0b013e3182718672

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  Postmortem magnetic resonance imaging of the heart ex situ: development of technical protocols.

Authors:  C Bruguier; C Egger; J P Vallée; J Grimm; X Boulanger; C Jackowski; P Mangin; S Grabherr
Journal:  Int J Legal Med       Date:  2014-08-10       Impact factor: 2.686

Review 2.  Clinical Importance of Myocardial T2 Mapping and Texture Analysis.

Authors:  Yasuo Amano; Yuko Omori; Chisato Ando; Fumi Yanagisawa; Yasuyuki Suzuki; Xiaoyan Tang; Hiroko Kobayashi; Ryo Takagi; Naoya Matsumoto
Journal:  Magn Reson Med Sci       Date:  2020-05-11       Impact factor: 2.471

Review 3.  Cardiovascular magnetic resonance imaging assessment of outcomes in acute myocardial infarction.

Authors:  Jamal N Khan; Gerry P McCann
Journal:  World J Cardiol       Date:  2017-02-26

Review 4.  Multimodality Imaging of Sudden Cardiac Death and Acute Complications in Acute Coronary Syndrome.

Authors:  Giuseppe Muscogiuri; Andrea Igoren Guaricci; Nicola Soldato; Riccardo Cau; Luca Saba; Paola Siena; Maria Grazia Tarsitano; Elisa Giannetta; Davide Sala; Paolo Sganzerla; Marco Gatti; Riccardo Faletti; Alberto Senatieri; Gregorio Chierchia; Gianluca Pontone; Paolo Marra; Mark G Rabbat; Sandro Sironi
Journal:  J Clin Med       Date:  2022-09-26       Impact factor: 4.964

5.  Cardiac T2 mapping: robustness and homogeneity of standardized in-line analysis.

Authors:  Marco Wiesmueller; Wolfgang Wuest; Rafael Heiss; Christoph Treutlein; Michael Uder; Matthias Stefan May
Journal:  J Cardiovasc Magn Reson       Date:  2020-05-28       Impact factor: 5.364

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.