Microclimate monitoring of Ariadne's house (Pompeii, Italy) for preventive conservation of fresco paintings.

Paloma Merello1, Fernando-Juan García-Diego, Manuel Zarzo.   

Abstract

BACKGROUND: Ariadne's house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions.
RESULTS: Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level.
CONCLUSIONS: The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments.

Entities:  

Year:  2012        PMID: 23190798      PMCID: PMC3541997          DOI: 10.1186/1752-153X-6-145

Source DB:  PubMed          Journal:  Chem Cent J        ISSN: 1752-153X            Impact factor:   4.215


  4 in total

1.  Indoor air climate requirements for Russian churches and cathedrals.

Authors:  Y Tabunschikov; M Brodatch
Journal:  Indoor Air       Date:  2004       Impact factor: 5.770

2.  Microclimate monitoring in the Carcer Tullianum: temporal and spatial correlation and gradients evidenced by multivariate analysis; first campaign.

Authors:  Giovanni Visco; Susanne Heidi Plattner; Patrizia Fortini; Serena Di Giovanni; Maria Pia Sammartino
Journal:  Chem Cent J       Date:  2012-05-02       Impact factor: 4.215

3.  An integrated approach to assess air pollution threats to cultural heritage in a semi-confined environment: the case study of Michelozzo's Courtyard in Florence (Italy).

Authors:  S Nava; F Becherini; A Bernardi; A Bonazza; M Chiari; I García-Orellana; F Lucarelli; N Ludwig; A Migliori; C Sabbioni; R Udisti; G Valli; R Vecchi
Journal:  Sci Total Environ       Date:  2009-11-25       Impact factor: 7.963

4.  Long-term monitoring of fresco paintings in the cathedral of Valencia (Spain) through humidity and temperature sensors in various locations for preventive conservation.

Authors:  Manuel Zarzo; Angel Fernández-Navajas; Fernando-Juan García-Diego
Journal:  Sensors (Basel)       Date:  2011-09-08       Impact factor: 3.576

  4 in total
  12 in total

1.  A multivariate approach for a comparison of big data matrices. Case study: thermo-hygrometric monitoring inside the Carcer Tullianum (Rome) in the absence and in the presence of visitors.

Authors:  Giovanni Visco; Susanne H Plattner; Patrizia Fortini; Mariapia Sammartino
Journal:  Environ Sci Pollut Res Int       Date:  2017-04-04       Impact factor: 4.223

2.  Statistical tools applied in the characterisation and evaluation of a thermo-hygrometric corrective action carried out at the Noheda archaeological site (Noheda, Spain).

Authors:  Miguel Ángel Valero; Paloma Merello; Ángel Fernández Navajas; Fernando-Juan García-Diego
Journal:  Sensors (Basel)       Date:  2014-01-17       Impact factor: 3.576

Review 3.  The Art of Designing Remote IoT Devices-Technologies and Strategies for a Long Battery Life.

Authors:  Gilles Callebaut; Guus Leenders; Jarne Van Mulders; Geoffrey Ottoy; Lieven De Strycker; Liesbet Van der Perre
Journal:  Sensors (Basel)       Date:  2021-01-29       Impact factor: 3.576

4.  Multivariate Time Series Analysis of Temperatures in the Archaeological Museum of L'Almoina (Valencia, Spain).

Authors:  Sandra Ramírez; Manuel Zarzo; Fernando-Juan García-Diego
Journal:  Sensors (Basel)       Date:  2021-06-26       Impact factor: 3.576

5.  Evaluation of corrective measures implemented for the preventive conservation of fresco paintings in Ariadne's house (Pompeii, Italy).

Authors:  Paloma Merello; Fernando-Juan García-Diego; Manuel Zarzo
Journal:  Chem Cent J       Date:  2013-05-17       Impact factor: 4.215

6.  Software for storage and management of microclimatic data for preventive conservation of cultural heritage.

Authors:  Angel Fernández-Navajas; Paloma Merello; Pedro Beltrán; Fernando-Juan García-Diego
Journal:  Sensors (Basel)       Date:  2013-02-27       Impact factor: 3.576

7.  Study of the effect of the strategy of heating on the mudejar church of Santa Maria in Ateca (Spain) for preventive conservation of the altarpiece surroundings.

Authors:  Fernando-Juan García-Diego; Angel Fernández-Navajas; Pedro Beltrán; Paloma Merello
Journal:  Sensors (Basel)       Date:  2013-08-26       Impact factor: 3.576

8.  Multivariate thermo-hygrometric characterisation of the archaeological site of Plaza de l'Almoina (Valencia, Spain) for preventive conservation.

Authors:  Angel Fernández-Navajas; Paloma Merello; Pedro Beltrán; Fernando-Juan García-Diego
Journal:  Sensors (Basel)       Date:  2013-07-29       Impact factor: 3.576

9.  Monitoring Heritage Buildings with Open Source Hardware Sensors: A Case Study of the Mosque-Cathedral of Córdoba.

Authors:  Francisco Javier Mesas-Carrascosa; Daniel Verdú Santano; Jose Emilio Meroño de Larriva; Rafael Ortíz Cordero; Rafael Enrique Hidalgo Fernández; Alfonso García-Ferrer
Journal:  Sensors (Basel)       Date:  2016-09-29       Impact factor: 3.576

10.  High Frequency Data Acquisition System for Modelling the Impact of Visitors on the Thermo-Hygrometric Conditions of Archaeological Sites: A Casa di Diana (Ostia Antica, Italy) Case Study.

Authors:  Paloma Merello; Fernando-Juan García-Diego; Pedro Beltrán; Claudia Scatigno
Journal:  Sensors (Basel)       Date:  2018-01-25       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.