Literature DB >> 23189303

Retention characteristics of different attachment systems of mandibular overdentures retained by two or three implants.

Bulent Uludag1, Serdar Polat.   

Abstract

PURPOSE: The purpose of this study was to quantify and compare the retentive forces of five different prosthetic attachment designs on mandibular overdentures retained by two or three implants.
MATERIALS AND METHODS: Two photoelastic acrylic resin models of an edentulous mandible were cast. In one model, three implants were aligned parallel to each other and oriented perpendicular to the occlusal plane. The distal implants were placed in the canine regions, with an interimplant distance of 22 mm. In the other model, two implants were placed using the same approach, with an interimplant distance of 22 mm. Five retention mechanisms were studied on both models: a bar with yellow clips, a milled galvanoformed bar, a bar with two clear distal locator attachments, a bar with two distal Ceka attachments, and a bar with clear locator attachments. Ten dentures were fabricated in clear acrylic resin. The specimens were loaded in tension at a crosshead speed of 50 mm/min in a universal testing machine. Five hundred forty cycles of repeated insertions and removals were performed to simulate 6 months of clinical function.
RESULTS: Initial retention forces ranged from 23.33 to 54.32 N. Retentive values of the clear locator attachments on the three-implant model were higher than those for other attachments.
CONCLUSION: All designs demonstrated a decrease in retention from the initial testing to the final pull-out test. This decrease was significant for all designs.

Entities:  

Mesh:

Year:  2012        PMID: 23189303

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study.

Authors:  Soumyadev Satpathy; C L Satish Babu; Shilpa Shetty; Bharat Raj
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

2.  Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures.

Authors:  Nesreen El Mekawy; Mohamed-Yosry Elhawary
Journal:  J Clin Exp Dent       Date:  2019-01-01

3.  How the initial retentive force of implant-supported overdentures can be affected with splinted and unsplinted attachments systems.

Authors:  Farahnaz Nejatidanesh; Omid Savabi; Ghazal Savabi; Mehdi Razavi
Journal:  Dent Res J (Isfahan)       Date:  2021-12-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.