Literature DB >> 2318930

Development of automated immunoassays for immune status screening and serodiagnosis of rubella virus infection.

G G Abbott1, J W Safford, R G MacDonald, M C Craine, R R Applegren.   

Abstract

The fully automated IMx immunoassay analyzer was used to develop a system for the detection of IgG and IgM antibodies to rubella virus for immune status screening and diagnosis of primary infections. Reagents and assay protocol software were developed using rubella virus sensitized microparticles as the solid phase to capture specific antibodies from serum samples. Anti-human IgG or IgM antibody coupled to alkaline phosphatase enzyme followed by methylumbelliferyl phosphate substrate was used to detect the presence or absence of antibodies specific to the antigens on the solid phase. To evaluate the efficacy of the IMx rubella IgG assay, immune status screening was performed with a clinical patient population of 501 sera. When compared to an IgG specific enzyme immunoassay and passive hemagglutination assay the agreement was greater than 99%. The IMx rubella IgM assay was utilized to determine the presence of rubella specific IgM antibodies in 462 sera. These results were compared to IgM specific enzyme immunoassay results and also demonstrated greater than 99% agreement. Seroconversion following rubella vaccination of susceptible individuals was demonstrated by IgG and IgM antibody responses as early as two weeks postvaccination. In addition to automation, the IMx system offers rapid assay times and calibration curve storage without sacrificing clinical efficacy.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2318930     DOI: 10.1016/0166-0934(90)90139-7

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  5 in total

1.  Automated microparticle enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii.

Authors:  J W Safford; G G Abbott; M C Craine; R G MacDonald
Journal:  J Clin Pathol       Date:  1991-03       Impact factor: 3.411

2.  Multicenter evaluation of five commercial rubella virus immunoglobulin G kits which report in international units per milliliter.

Authors:  W Dimech; A Bettoli; D Eckert; B Francis; J Hamblin; T Kerr; C Ryan; I Skurrie
Journal:  J Clin Microbiol       Date:  1992-03       Impact factor: 5.948

3.  Comparison of novel synthetic peptide-based DETECT-RUBELLA enzyme immunoassays with Enzygnost and IMx for detection of rubella-specific immunoglobulin G.

Authors:  L Pedneault; M Zrein; L Robillard; F Landry; M Lacroix; J Joncas
Journal:  J Clin Microbiol       Date:  1994-04       Impact factor: 5.948

Review 4.  Standardization of Assays That Detect Anti-Rubella Virus IgG Antibodies.

Authors:  Wayne Dimech; Liliane Grangeot-Keros; Christelle Vauloup-Fellous
Journal:  Clin Microbiol Rev       Date:  2016-01       Impact factor: 26.132

5.  Comparison of five methods for the determination of rubella immunity.

Authors:  R L Sautter; A E Crist; L M Johnson; W D Lebar
Journal:  Infect Dis Obstet Gynecol       Date:  1994
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.