The effect of impression technique and implant angulation on the impression accuracy of external- and internal-connection implants.

Pavlos Mpikos1, Nikolaos Kafantaris, Dimitrios Tortopidis, Christos Galanis, George Kaisarlis, Petros Koidis.   

Abstract

PURPOSE: The purpose of this in vitro study was to investigate the effect of impression technique and implant angulation on the impression accuracy of external- and internal-connection implants using a novel experimental device.
MATERIALS AND METHODS: An experimental device was designed and fabricated to make in vitro impressions by means of open- and closed-tray techniques. Impressions of eight implants with two different connections (four external-hex and four internal-hex) at three angulations (0, 15, and 25 degrees) were made using a medium-consistency polyether material. Evaluation of implant impression accuracy was carried out by directly measuring the difference in coordinate values between the implant body/impression coping positioned on the base and the impression coping/laboratory analog positioned in the impression using a touch-probe coordinate measuring machine. Experimental data were analyzed by two-way analysis of variance. The significance level of all hypothesis testing procedures was set at P<.05.
RESULTS: The results showed that: (1) for implants with external connections, impression accuracy is not significantly affected by the impression technique, implant angulation, or their interaction; and (2) for implants with internal connections, impression accuracy is significantly affected only by implant angulation: Impression inaccuracy was greater at the 25-degree implant angulation.
CONCLUSIONS: Within the limitations of this in vitro study, the open- and closed-tray techniques had no effect on the accuracy of multiple implant impressions. The interaction between impression technique and implant angulation was also not significant. However, implant angulation significantly affected the impression accuracy when implants with internal connections were used.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23189292

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Comparison of the accuracy of different impression procedures in case of multiple and angulated implants : Accuracy of impressions in multiple and angulated implants.

Authors:  M Wafa Richi; Sevcan Kurtulmus-Yilmaz; Oguz Ozan
Journal:  Head Face Med       Date:  2020-05-04       Impact factor: 2.151

2.  Comparison of the accuracy of open-tray and snap-on impression techniques of implants with different angulations.

Authors:  Abbass Fallah Tafti; Mahnaz Hatami; Foroughsadat Razavi; Behnaz Ebadian
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12

3.  Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions.

Authors:  Hakimeh Siadat; Zeinab Saeidi; Marzieh Alikhasi; Somayeh Zeighami
Journal:  J Clin Exp Dent       Date:  2018-11-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.